Examination of ceramic restorative material interfacial debonding using acoustic emission and optical coherence tomography.

Chun-Li Lin1, Wen-Chuan Kuo, Jin-Jie Yu, Shao-Fu Huang.   

Abstract

OBJECTIVE: CAD/CAM ceramic restorative material is routinely bonded to tooth substrates using adhesive cement. This study investigates micro-crack growth and damage in the ceramic/dentin adhesive interface under fatigue shear testing monitored using the acoustic emission (AE) technique with optical coherence tomography (OCT).
METHODS: Ceramic/dentin adhesive samples were prepared to measure the shear bond strength (SBS) under static load. Fatigue shear testing was performed using a modified ISO14801 method. Loads in the fatigue tests were applied at 80%, 70%, and 60% of the SBS to monitor interface debonding. The AE technique was used to detect micro-crack signals in static and fatigue shear bond tests.
RESULTS: The results showed that the average SBS value in the static tests was 10.61±2.23MPa (mean±standard deviation). The average number of fatigue cycles in which ceramic/dentin interface damage was detected in 80%, 70% and 60% of the SBS were 152, 1962 and 9646, respectively. The acoustic behavior varied according to the applied load level. Events were emitted during 60% and 70% fatigue tests. A good correlation was observed between crack location in OCT images and the number of AE signal hits. SIGNIFICANCE: The AE technique and OCT images employed in this study could potentially be used as a pre-clinical assessment tool to determine the integrity of cemented load bearing restored ceramic material. Sustainable cyclic load stresses in ceramic/dentin-bonded specimens were substantially lower than the measured SBS. Predicted S-N curve showed that the maximum endured load was 4.18MPa passing 10(6) fatigue cyclic.
Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23337286     DOI: 10.1016/j.dental.2012.12.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  3 in total

1.  Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring.

Authors:  Shao-Fu Huang; Wan-Rung Chen; Chun-Li Lin
Journal:  Biomed Eng Online       Date:  2016-02-24       Impact factor: 2.819

Review 2.  The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review.

Authors:  Monika Machoy; Julia Seeliger; Liliana Szyszka-Sommerfeld; Robert Koprowski; Tomasz Gedrange; Krzysztof Woźniak
Journal:  J Healthc Eng       Date:  2017-07-16       Impact factor: 2.682

3.  Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing.

Authors:  Yen-Hsiang Chang; Jin-Jie Yu; Chun-Li Lin
Journal:  Biomed Eng Online       Date:  2014-12-13       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.