Literature DB >> 23335653

Is the chimney graft technique a safe and feasible approach to treat urgent aneurysm and pseudoaneurysm of the abdominal aorta? An analysis of our experience and technical considerations.

Andrea Siani1, Federico Accrocca, Roberto Gabrielli, Giustino Marcucci.   

Abstract

The chimney graft (CG) technique, based on the deployment of a covered stent parallel to the aortic endograft, has been proposed to achieve a safe proximal fixation extending the sealing zone. We report our experience with the CG technique in an emergency setting. Between December 2010 and April 2012, 4 patients underwent the CG technique. The mean age was 79 (range 76-82 years) and 3 patients were men. The median aneurysm diameter was 64.7 mm (range 63-68 mm). Indications for CG were painful proximal para-anastomotic aneurysm in 2 cases and symptomatic juxtarenal aneurysm in the other 2. Target vessels were both the renal arteries. Technical success was achieved in 100% and no intraoperative complications occurred. No stent-related complications, or Type I endoleak, were detected. No death occurred during the postoperative course. Creatinine elevation was observed in 2 cases. At follow-up, no endoleaks or rupture occurred. One patient died of myocardial infarction 3 months after the procedure. The primary patency rate of covered stents was 100%. The CG technique seems to be safe and feasible with an excellent patency rate of covered stents and a low incidence of endoleaks. More evidence in the literature is needed to carry out a validation of this technique in an emergency.

Entities:  

Mesh:

Year:  2013        PMID: 23335653      PMCID: PMC3630419          DOI: 10.1093/icvts/ivs572

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  8 in total

1.  Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.

Authors:  Konstantinos P Donas; Felice Pecoraro; Giovanni Torsello; Mario Lachat; Martin Austermann; Dieter Mayer; Giuseppe Panuccio; Zoran Rancic
Journal:  J Vasc Surg       Date:  2011-12-09       Impact factor: 4.268

2.  The chimney procedure is an emergently available endovascular solution for visceral aortic aneurysm rupture.

Authors:  Felix J V Schlösser; John E Aruny; Carter B Freiburg; Hamid R Mojibian; Bauer E Sumpio; Bart E Muhs
Journal:  J Vasc Surg       Date:  2011-01-26       Impact factor: 4.268

3.  Technical aspects, current indications, and results of chimney grafts for juxtarenal aortic aneurysms.

Authors:  Raphael Coscas; Hicham Kobeiter; Pascal Desgranges; Jean-Pierre Becquemin
Journal:  J Vasc Surg       Date:  2011-04-22       Impact factor: 4.268

4.  The chimney graft: a technique for preserving or rescuing aortic branch vessels in stent-graft sealing zones.

Authors:  Tomas Ohrlander; Björn Sonesson; Krasnodar Ivancev; Timothy Resch; Nuno Dias; Martin Malina
Journal:  J Endovasc Ther       Date:  2008-08       Impact factor: 3.487

5.  "The chimney graft"-a simple technique for endovascular repair of complex juxtarenal abdominal aortic aneurysms in no-option patients.

Authors:  Suhail Allaqaband; M Fuad Jan; Tanvir Bajwa
Journal:  Catheter Cardiovasc Interv       Date:  2010-06-01       Impact factor: 2.692

Review 6.  The chimney graft technique for preserving visceral vessels during endovascular treatment of aortic pathologies.

Authors:  Konstantinos G Moulakakis; Spyridon N Mylonas; Efthimios Avgerinos; Anastasios Papapetrou; John D Kakisis; Elias N Brountzos; Christos D Liapis
Journal:  J Vasc Surg       Date:  2012-01-10       Impact factor: 4.268

7.  Endovascular chimney technique versus open repair of juxtarenal and suprarenal aneurysms.

Authors:  Kevin J Bruen; Robert J Feezor; Michael J Daniels; Adam W Beck; W Anthony Lee
Journal:  J Vasc Surg       Date:  2011-01-06       Impact factor: 4.268

8.  Outcome of renal stenting for renal artery coverage during endovascular aortic aneurysm repair.

Authors:  Jade S Hiramoto; Catherine K Chang; Linda M Reilly; Darren B Schneider; Joseph H Rapp; Timothy A M Chuter
Journal:  J Vasc Surg       Date:  2009-02-23       Impact factor: 4.268

  8 in total