Literature DB >> 23334456

Characteristics and composition of fouling caused by pig slurry in a tubular heat exchanger--recommended cleaning systems.

C Cunault1, Y Coquinot, C H Burton, S Picard, A M Pourcher.   

Abstract

The structure and composition of the fouling deposits caused by pig slurry heated in a tubular heat exchanger were characterized to understand their formation and thus be able to minimize fouling and define effective routine cleaning methods. Two temperatures (55 °C and 80 °C) were investigated. Two types of fouling were identified: organic/mineral and biofilm. The first only formed at temperatures above 50 °C, often during the heating phase, and was the main problem encountered in treatments at 80 °C. Organic/mineral deposits formed a thin compact sub-layer and a thick porous top layer composed of 67-76% minerals, 9-15% proteins, 8-20% carbohydrates and 0-5% fats. Biofilms formed at temperatures between 25 °C and 70 °C in both the cooling and heating sections of the exchanger. This type of fouling predominated at temperatures below 55 °C. The biofilm covered a thin mineral base layer. Strongly acidic or alkaline washing cycle are recommended to clean Type I deposits, while in-line gas-rumbling is recommended for Type II fouling.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23334456     DOI: 10.1016/j.jenvman.2012.12.017

Source DB:  PubMed          Journal:  J Environ Manage        ISSN: 0301-4797            Impact factor:   6.789


  1 in total

1.  Bamboo Plantations for Phytoremediation of Pig Slurry: Plant Response and Nutrient Uptake.

Authors:  Julien Piouceau; Frédéric Panfili; Grégory Bois; Matthieu Anastase; Frédéric Feder; Julien Morel; Véronique Arfi; Laurent Dufossé
Journal:  Plants (Basel)       Date:  2020-04-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.