Literature DB >> 23333056

Biomechanical evaluation of subtalar fusion: the influence of screw configuration and placement.

Sven Hungerer1, Sebastian Eberle, Susanne Lochner, Michael Maier, Florian Högel, Rainer Penzkofer, Peter Augat.   

Abstract

Common surgical procedures for subtalar fusion include joint resection, autologous bone grafting, and osteosynthesis with screws in a parallel screw configuration. Although fusion is a routine procedure, the reported rates of nonunion have been high. The present study assessed different screw configurations in terms of their rotational and bending stability in an artificial bone model and cadaver bone. Arthrodesis was always performed with 2 screws. Three different screw configurations were tested: parallel, counter-parallel, and a delta configuration. Two different screw designs were used: a cannulated, partially threaded screw (6.5-mm and 8.0-mm diameter) and a solid screw with a different thread design. Eight experimental groups were investigated as pilot studies in artificial bones and then 3 groups in cadaver bones. The parameters were the primary stiffness and deflection of the construct for loads simulating the internal-external rotation and supination-pronation. Delta positioning of the screws resulted in the greatest biomechanical stiffness and the lowest degrees of deflection of the arthrodesis in the artificial bones and cadaver bones. Increasing the screw diameter from 6.5 to 8.0 mm resulted in no additional stability of the arthrodesis in the artificial bones. The results of the present study have indicated that the delta configuration for arthrodesis results in the greatest construct stiffness and lower relative deflection between the talus and calcaneus in the positions tested.
Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2013        PMID: 23333056     DOI: 10.1053/j.jfas.2012.11.014

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  4 in total

1.  Subtalar arthrodesis stabilisation with screws in an angulated configuration is superior to the parallel disposition: a biomechanical study.

Authors:  Martin Eichinger; Werner Schmölz; Alexander Brunner; Raul Mayr; Andreas Bölderl
Journal:  Int Orthop       Date:  2015-08-08       Impact factor: 3.075

2.  Fusion of the subtalar joint for post-traumatic arthrosis: a study of functional outcomes and non-unions.

Authors:  Patrick Ziegler; Jan Friederichs; Sven Hungerer
Journal:  Int Orthop       Date:  2017-05-08       Impact factor: 3.075

3.  Screw tip augmentation leads to improved primary stability in the minimally invasive treatment of displaced intra-articular fractures of the calcaneus: a biomechanical study.

Authors:  Martin Eichinger; Alexander Brunner; Hannes Stofferin; Andreas Bölderl; Michael Blauth; Werner Schmölz
Journal:  Int Orthop       Date:  2018-10-10       Impact factor: 3.075

4.  Effects of five hindfoot arthrodeses on foot and ankle motion: Measurements in cadaver specimens.

Authors:  Kun Zhang; Yanxi Chen; Minfei Qiang; Yini Hao
Journal:  Sci Rep       Date:  2016-10-18       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.