Literature DB >> 23329654

Parotid fat contents in healthy subjects evaluated with iterative decomposition with echo asymmetry and least squares fat-water separation.

Hing-Chiu Chang1, Chun-Jung Juan, Hui-Chu Chiu, Yi-Jui Liu, Cheng-Chieh Cheng, Su-Chin Chiu, Cheng-Yu Chen, Guo-Shu Huang, Hsiao-Wen Chung.   

Abstract

PURPOSE: To evaluate the effectiveness of three fat measurement methods for parotid glands in healthy subjects, with or without metallic dental implants.
MATERIALS AND METHODS: The institutional review board approved this study, with informed consent obtained from 114 volunteers undergoing magnetic resonance (MR) imaging at 1.5 T. Fat-saturated (FS) and non-fat-saturated (NFS) fast spin-echo T1-weighted imaging (T1 method), FS and NFS T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction fast spin-echo imaging (T2 method), and gradient-echo imaging with fat-water separation using iterative decomposition with echo asymmetry and least squares (IDEAL) method were used to derive parotid fat contents. Two raters examined the homogeneity of fat saturation to determine whether parotid fat quantification was successful, with the success rate in the 114 subjects recorded for each protocol. In subjects whose fat quantification was successful with all three imaging methods, linear regression was used to analyze the correlation between any pair of the three parotid fat content measurement methods.
RESULTS: Success rates in parotid fat measurements by using T1, T2, and IDEAL methods were 87.7% (100 of 114), 87.7% (100 of 114), and 100% (114 of 114), respectively. The means of measured parotid fat contents revealed significant differences (P < .001) between any pair of the three measurement methods. The parotid fat contents measured with the three methods were significantly correlated with each other between any pair of combinations.
CONCLUSION: The IDEAL method provided a high success rate for parotid fat measurements, even in subjects with metallic dental implants.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23329654     DOI: 10.1148/radiol.12112599

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Usefulness of IDEAL T2 imaging for homogeneous fat suppression and reducing susceptibility artefacts in brachial plexus MRI at 3.0 T.

Authors:  Alberto Tagliafico; Bianca Bignotti; Giulio Tagliafico; Carlo Martinoli
Journal:  Radiol Med       Date:  2015-08-08       Impact factor: 3.469

2.  Clinical usefulness of the mDIXON Quant the method for estimation of the salivary gland fat fraction: comparison with MR spectroscopy.

Authors:  Yoshitaka Kise; Toru Chikui; Yasuo Yamashita; Koji Kobayashi; Kazunori Yoshiura
Journal:  Br J Radiol       Date:  2017-07-14       Impact factor: 3.039

3.  Estimation of proton density fat fraction of the salivary gland.

Authors:  Toru Chikui; Yasuo Yamashita; Yoshitaka Kise; Tomonori Saito; Kazutoshi Okamura; Kazunori Yoshiura
Journal:  Br J Radiol       Date:  2018-02-06       Impact factor: 3.039

4.  Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation.

Authors:  Hing-Chiu Chang; Chun-Jung Juan; Hui-Chu Chiu; Cheng-Chieh Cheng; Su-Chin Chiu; Yi-Jui Liu; Hsiao-Wen Chung; Hsian-He Hsu
Journal:  Eur Radiol       Date:  2014-06-28       Impact factor: 5.315

5.  Effect of laterality, gender, age and body mass index on the fat fraction of salivary glands in healthy volunteers: assessed using iterative decomposition of water and fat with echo asymmetry and least-squares estimation method.

Authors:  Guo-Yi Su; Chuan-Bing Wang; Hao Hu; Jun Liu; Hong-Yuan Ding; Xiao-Quan Xu; Fei-Yun Wu
Journal:  Dentomaxillofac Radiol       Date:  2018-10-26       Impact factor: 2.419

6.  Early evaluation of radiation-induced parotid damage in patients with nasopharyngeal carcinoma by T2 mapping and mDIXON Quant imaging: initial findings.

Authors:  Nan Zhou; Chen Chu; Xin Dou; Weibo Chen; Jian He; Jing Yan; Zhengyang Zhou; Xiaofeng Yang
Journal:  Radiat Oncol       Date:  2018-02-08       Impact factor: 3.481

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.