Literature DB >> 23329538

A titanium plasma-sprayed cup with and without hydroxyapatite-coating: a randomised radiostereometric study of stability and osseointegration.

Urs Munzinger1, Thomas Guggi, Bart Kaptein, Marion Persoon, Edward Valstar, H Cornelis Doets.   

Abstract

We present a prospective, two-centre radiostereometric analysis (RSA) regarding the stability of a flattened pole titanium press-fit cup (EP-FIT PLUS), and whether additional hydroxyapatite coating leads to faster bone ingrowth into the porous coating. Forty-two postmenopausal female patients (44 hips) undergoing total hip arthroplasty for primary osteoarthritis, selected to avoid hormonal factors influencing bone metabolism, were randomised to receive this cup with a titanium-plasma-sprayed surface with or without an additional hydroxyapatite coating. RSA was used to measure cup translation and rotation along three cardinal axes with respect to the host bone at the following time points: immediately postoperatively, at 6 weeks, and at 3, 6, 12, and 24 months. The most pronounced translation was proximal (0.11 mm) and posterior tilt (-0.27°). No difference in translation and rotation could be detected between the two groups. With the exception of one cup with an isolated radiolucent line <2 mm in zone 1, all cups showed complete osseointegration on conventional radiographs. The flattened pole cup provided excellent early stability and no advantage could be detected with additional hydroxyapatite coating.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23329538     DOI: 10.5301/HIP.2013.10598

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

Review 1.  Do outcomes reported in randomised controlled trials of joint replacement surgery fulfil the OMERACT 2.0 Filter? A review of the 2008 and 2013 literature.

Authors:  Peter D H Wall; Bethan L Richards; Andrew Sprowson; Rachelle Buchbinder; Jasvinder A Singh
Journal:  Syst Rev       Date:  2017-05-30

2.  Comparison of early migration patterns between a ceramic and polyethylene liner in uncemented Trabecular Titanium cups: a 2-year randomized controlled trial of 52 hips using radiostereometric analysis.

Authors:  Amanda D Klaassen; Elisabeth A Schäffer; Nienke W Willigenburg; Loes W A H Van Beers; Vanessa A B Scholtes; Victor P M Van der Hulst; Lennard A Koster; Bart L Kaptein; Dirk Jan F Moojen; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2022-04-28       Impact factor: 3.925

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.