Literature DB >> 23327836

The effect of a knee ankle foot orthosis incorporating an active knee mechanism on gait of a person with poliomyelitis.

Mokhtar Arazpour1, Ahmad Chitsazan, Monireh Ahmadi Bani, Gholamreza Rouhi, Farhad Tabatabai Ghomshe, Stephen W Hutchins.   

Abstract

BACKGROUND: The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. CASE DESCRIPTION AND METHODS: A knee ankle foot orthosis was initially manufactured by incorporating drop lock knee joints and custom molded ankle foot orthoses and fitted to a person with poliomyelitis. The orthosis was then adapted by adding electrically activated powered knee joints to provide knee extension torque during stance and also flexion torque in swing phase. Lower limb kinematic and kinetic data plus data for temporospatial parameters were acquired from three test walks using each orthosis. FINDINGS AND OUTCOMES: Walking speed, step length, and vertical and horizontal displacement of the pelvis decreased when walking with the powered stance control knee ankle foot orthosis compared to the knee ankle foot orthosis. When using the powered stance control knee ankle foot orthosis, the knee flexion achieved during swing and also the overall pattern of walking more closely matched that of normal human walking. The reduced walking speed may have caused the smaller compensatory motions detected when the powered stance control knee ankle foot orthosis was used.
CONCLUSION: The new powered SCKAFO facilitated controlled knee flexion and extension during ambulation for a volunteer poliomyelitis person.

Entities:  

Keywords:  Knee ankle foot orthosis; active knee mechanism; gait; poliomyelitis

Mesh:

Year:  2013        PMID: 23327836     DOI: 10.1177/0309364612469140

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  4 in total

Review 1.  The influence of orthosis options on walking parameters in spinal cord-injured patients: a literature review.

Authors:  M Arazpour; M Samadian; K Ebrahimzadeh; M Ahmadi Bani; S W Hutchins
Journal:  Spinal Cord       Date:  2016-02-09       Impact factor: 2.772

2.  Therapeutic Experience on Stance Control Knee-Ankle-Foot Orthosis With Electromagnetically Controlled Knee Joint System in Poliomyelitis.

Authors:  Jung-Hwan Kim; Sang-Goo Ji; Kang-Jae Jung; Jae-Hyung Kim
Journal:  Ann Rehabil Med       Date:  2016-04-25

3.  Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments.

Authors:  Antonio Rodríguez-Fernández; Joan Lobo-Prat; Josep M Font-Llagunes
Journal:  J Neuroeng Rehabil       Date:  2021-02-01       Impact factor: 4.262

Review 4.  Review of control strategies for lower-limb exoskeletons to assist gait.

Authors:  Romain Baud; Ali Reza Manzoori; Auke Ijspeert; Mohamed Bouri
Journal:  J Neuroeng Rehabil       Date:  2021-07-27       Impact factor: 4.262

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.