Literature DB >> 23325044

Clinical relevance of slow ventricular tachycardia in heart failure patients with primary prophylactic implantable cardioverter defibrillator indication.

Ulrich Lüsebrink1, David Duncker, Michaela Hess, Irma Heinrichs, Ajmal Gardiwal, Hanno Oswald, Thorben König, Gunnar Klein.   

Abstract

AIMS: Implantable cardioverter defibrillators (ICDs) have shown to reduce all-cause mortality in heart failure patients. In SCD-HeFT study, ICDs were programmed with a detection zone of ≥ 187 b.p.m. Thus, the incidence and clinical significance of slower ventricular tachycardias (VTs) in these patients remains largely unknown, though clinically important for device selection, programming, and follow-up. METHODS AND
RESULTS: We prospectively studied symptomatic heart failure patients with an indication for a primary prophylactic ICD with or without concomitant resynchronization therapy according to SCD-HeFT inclusion criteria. Devices were programmed to an additional monitor zone for slow VTs at heart rates 130-186 b.p.m. Two hundred consecutive patients (86% male) were followed for a mean of 509 ± 308 days. One hundred and thirty-seven patients (68.5%) were New York Heart Association class III, 75 patients (37.5%) were on cardiac resynchronization therapy, and 124 (62%) had ischaemic cardiomyopathy. We observed 473 VT episodes in 36 patients (18%) and 131 ventricular fibrillation episodes in 30 patients (15%). Ventricular tachycardia overall occurred in 40 patients (20%). The incidence of slow VTs was low in only 12 patients (6%). No patient with slow VT suffered from syncope, palpitation, or decompensation leading to hospitalization. We did not find any reliable predictor for increased long-term risk of slow VTs.
CONCLUSION: Incidence of slow VTs in a typical heart failure population with primary prophylactic ICD-implantation ± resynchronization therapy is very low. Slow VTs detected in the ICD monitor zone remained clinically asymptomatic. Thus, single chamber and atriobiventricular ICDs with a VT/ventricular fibrillation zone of ≥ 187 b.p.m. and one burst before shock delivery might be sufficient and pragmatic for the vast majority of these patients.

Entities:  

Keywords:  Heart failure; ICD; Slow VT; Ventricular arrhythmia

Mesh:

Year:  2013        PMID: 23325044     DOI: 10.1093/europace/eus430

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

Review 1.  Ventricular Tachycardia with ICD Shocks: When to Medicate and When to Ablate.

Authors:  Amir AbdelWahab; John Sapp
Journal:  Curr Cardiol Rep       Date:  2017-09-13       Impact factor: 2.931

2.  Slow ventricular tachycardia presenting with acute liver failure.

Authors:  Andreas Wannhoff; Christian Nusshag; Wolfgang Stremmel; Uta Merle
Journal:  SAGE Open Med Case Rep       Date:  2017-07-12
  2 in total