cobas 8000 Modular analyzer series evaluated under routine-like conditions at 14 sites in Australia, Europe, and the United States.

Arnold von Eckardstein1, Hans Jürgen Roth, Graham Jones, Sharon Preston, Thomas Szekeres, Roland Imdahl, Marc Conti, Norbert Blanckaert, Darren Jose, Joachim Thiery, Lisa Feldmann, Nicolas von Ahsen, Massimo Locatelli, Jenni Kremastinou, Albert Kunst, Arnulf Hubbuch, Margaret McGovern.   

Abstract

Clinical laboratories need to test patient samples precisely, accurately, and efficiently. The latest member of the Roche cobas modular platform family, the cobas 8000 modular analyzer series allows compact and convenient consolidation of clinical chemistry and immunochemistry assays in high-workload laboratories with a throughput of 3 to 15 million tests annually. Here we present the results of studies designed to test the overall system performance under routine-like conditions that were conducted at 14 laboratories over 2 y. Experiments that test analytical performance of the new module were integrated with overall system functionality testing of all modules in different configurations. More than two million results were generated and evaluated for ~100 applications using serum/plasma, urine, or EDTA blood samples. During the workflow studies, eight configurations of the possible 38 combinations were used, covering all available analytical modules. The versatility of the module combinations makes the system customizable to fit the needs of diverse laboratories, allowing precise and accurate analysis of a broad spectrum of clinical chemistry and immunochemistry parameters with short turnaround times. This new system will contribute to the ability of clinical laboratories to offer better service to their customers and support vital clinical decision making.

Entities:  

Keywords:  analytical modules; analytical performance; analyzers; practicability assessment; workflow analysis

Mesh:

Year:  2013        PMID: 23321915     DOI: 10.1177/2211068212472183

Source DB:  PubMed          Journal:  J Lab Autom        ISSN: 2211-0682


  3 in total

1.  The Influence of Salt Sensitivity Phenotype on Sodium Excretion and Diuresis: A Chrononutrition Pilot Study.

Authors:  Upeksha Sewwandi Alwis; Irina Verbakel; Kim Pauwaert; Joris Delanghe; Lien Dossche; John Van Camp; Saskia Roggeman; Karel Everaert
Journal:  Int J Clin Pract       Date:  2022-01-31       Impact factor: 3.149

2.  Fasting plasma glucose as initial screening for diabetes and prediabetes in irish adults: The Diabetes Mellitus and Vascular health initiative (DMVhi).

Authors:  Margaret Sinnott; Brendan T Kinsley; Abaigeal D Jackson; Cathal Walsh; Tony O'Grady; John J Nolan; Peter Gaffney; Gerard Boran; Cecily Kelleher; Bernadette Carr
Journal:  PLoS One       Date:  2015-04-15       Impact factor: 3.240

3.  Triage Strategies Based on C-Reactive Protein Levels and SARS-CoV-2 Tests among Individuals Referred with Suspected COVID-19: A Prospective Cohort Study.

Authors:  Erika Olivia Boyesen; Ida Maria Balsby; Marius Henriksen; Robin Christensen; Jens Henning Rasmussen; Finn Erland Nielsen; Hanne Nygaard; Lennart Jan Friis-Hansen; Susanne Dam Nielsen; Rebekka Faber Thudium; Celeste Porsberg; Lars Erik Kristensen; Henning Bliddal
Journal:  J Clin Med       Date:  2021-12-30       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.