Literature DB >> 23318819

[Effect of different levels of glucose in the dialysate on the risk of hypoglycaemia during hemodialysis in diabetic patients].

Jayme Eduardo Burmeister1, Juliana Fernandes Campos, Diego da Rosa Miltersteiner.   

Abstract

INTRODUCTION: Hypoglycemia can occur during hemodialysis in diabetic chronic renal failure patients when using a dialysate without glucose. With dialysis solutions with glucose 90 mg/dL or more, this is preventable, but diabetic patients could present higher intradialytic glycemias.
OBJECTIVE: We tested a dialytic fluid with a lower level of glucose trying to prevent both hypo and hyperglycemia in these patients.
METHODS: Twenty diabetic individuals from our hemodialysis unit were submitted to 3 sessions with dialysis solutions with two different glucose concentrations--55 mg/dL (Phase 55), and 90 mg/dL (Phase 90)--and a glucose-free one (Phase ZERO). Plasma glucose levels were measured at five moments during each session--before and at 30, 60, 90 and 240 min. Results under 70 mg/dL were considered as hypoglycemia.
RESULTS: Three patients presented 6 episodes of hypoglycemia in Phase 55, but no patient presented any episode in Phase 90. In Phase ZERO, five patients presented 7 episodes.
CONCLUSION: This dialysate with a low level of glucose (55 mg/dL) did not prevent hypoglycemia episodes during hemodialysis in diabetic patients, these occurrences being similar to that when using a dialysate without glucose. The use of a 90 mg/dL glucose dialysis solution did not induce higher intradialytic glycemia levels than the other dialysis solutions.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23318819     DOI: 10.5935/0101-2800.20120020

Source DB:  PubMed          Journal:  J Bras Nefrol        ISSN: 0101-2800


  2 in total

1.  Epidemiology and outcomes of hypoglycemia in patients with advanced diabetic kidney disease on dialysis: A national cohort study.

Authors:  Yeh-Wen Chu; Hsuan-Ming Lin; Jhi-Joung Wang; Shih-Feng Weng; Chih-Ching Lin; Chih-Chiang Chien
Journal:  PLoS One       Date:  2017-03-29       Impact factor: 3.240

2.  Validation and applicability of an alternative method for dialysis water and dialysate quality analysis.

Authors:  Gabriela Corrêa Carvalho; Adriana Bugno; Adriana Aparecida Buzzo Almodovar; Fernando Pontes de Lima E Silva; Terezinha de Jesus Andreoli Pinto
Journal:  J Bras Nefrol       Date:  2020-04-30
  2 in total