Literature DB >> 23318487

Bedside estimation of nonaerated lung tissue using blood gas analysis.

Andreas W Reske1, Eduardo L V Costa, Alexander P Reske, Anna Rau, João B Borges, Marcelo A Beraldo, Udo Gottschaldt, Matthias Seiwerts, Dierk Schreiter, David Petroff, Udo X Kaisers, Hermann Wrigge, Marcelo B P Amato.   

Abstract

OBJECTIVES: Studies correlating the arterial partial pressure of oxygen to the fraction of nonaerated lung assessed by CT shunt yielded inconsistent results. We systematically analyzed this relationship and scrutinized key methodological factors that may compromise it. We hypothesized that both physiological shunt and the ratio between PaO2 and the fraction of inspired oxygen enable estimation of CT shunt at the bedside.
DESIGN: : Prospective observational clinical and laboratory animal investigations.
SETTING: ICUs (University Hospital Leipzig, Germany) and Experimental Pulmonology Laboratory (University of São Paulo, Brazil). PATIENTS, SUBJECTS AND
INTERVENTIONS: Whole-lung CT and arterial blood gases were acquired simultaneously in 77 patients mechanically ventilated with pure oxygen. A subgroup of 28 patients was submitted to different Fio2. We also studied 19 patients who underwent repeat CT. Furthermore we studied ten pigs with acute lung injury at multiple airway pressures, as well as a theoretical model relating PaO2 and physiological shunt. We logarithmically transformed the PaO2/Fio2 to change this nonlinear relationship into a linear regression problem.
MEASUREMENTS AND MAIN RESULTS: We observed strong linear correlations between Riley's approximation of physiological shunt and CT shunt (R = 0.84) and between logarithmically transformed PaO2/Fio2 and CT shunt (R = 0.86), allowing us to construct a look-up table with prediction intervals. Strong linear correlations were also demonstrated within-patients (R = 0.95). Correlations were significantly improved by the following methodological issues: measurement of PaO2/Fio2 during pure oxygen ventilation, use of logarithmically transformed PaO2/Fio2 instead of the "raw" PaO2/Fio2, quantification of nonaerated lung as percentage of total lung mass and definition of nonaerated lung by the [-200 to +100] Hounsfield Units interval, which includes shunting units within less opacified lung regions.
CONCLUSION: During pure oxygen ventilation, logarithmically transformed PaO2/Fio2 allows estimation of CT shunt and its changes in patients during systemic inflammation. Relevant intrapulmonary shunting seems to occur in lung regions with CT numbers between [-200 and +100] Hounsfield Units.

Entities:  

Mesh:

Year:  2013        PMID: 23318487     DOI: 10.1097/CCM.0b013e3182711b6e

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

Review 1.  Fifty Years of Research in ARDS. Setting Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome.

Authors:  Sarina K Sahetya; Ewan C Goligher; Roy G Brower
Journal:  Am J Respir Crit Care Med       Date:  2017-06-01       Impact factor: 21.405

Review 2.  Mechanical ventilation in COVID-19: A physiological perspective.

Authors:  John N Cronin; Luigi Camporota; Federico Formenti
Journal:  Exp Physiol       Date:  2021-09-27       Impact factor: 2.858

3.  Experimental blunt chest trauma--cardiorespiratory effects of different mechanical ventilation strategies with high positive end-expiratory pressure: a randomized controlled study.

Authors:  Dierk Schreiter; Nadja C Carvalho; Sebastian Katscher; Ludger Mende; Alexander P Reske; Peter M Spieth; Alysson R Carvalho; Alessandro Beda; Burkhard Lachmann; Marcelo B P Amato; Hermann Wrigge; Andreas W Reske
Journal:  BMC Anesthesiol       Date:  2016-01-12       Impact factor: 2.217

4.  Mechanical Ventilation Strategies Targeting Different Magnitudes of Collapse and Tidal Recruitment in Porcine Acid Aspiration-Induced Lung Injury.

Authors:  Juliane Haase; Dorina C Buchloh; Sören Hammermüller; Peter Salz; Julia Mrongowius; Nadja C Carvalho; Alessandro Beda; Anna Rau; Henning Starke; Peter M Spieth; Claudia Gittel; Thomas Muders; Hermann Wrigge; Andreas W Reske
Journal:  J Clin Med       Date:  2019-08-18       Impact factor: 4.241

5.  Mechanical Ventilation Redistributes Blood to Poorly Ventilated Areas in Experimental Lung Injury.

Authors:  John N Cronin; Douglas C Crockett; Andrew D Farmery; Göran Hedenstierna; Anders Larsson; Luigi Camporota; Federico Formenti
Journal:  Crit Care Med       Date:  2020-03       Impact factor: 7.598

Review 6.  Functional pathophysiology of SARS-CoV-2-induced acute lung injury and clinical implications.

Authors:  Nader M Habashi; Luigi Camporota; Louis A Gatto; Gary Nieman
Journal:  J Appl Physiol (1985)       Date:  2021-01-14

Review 7.  Pathophysiology of coronavirus-19 disease acute lung injury.

Authors:  Luigi Camporota; John N Cronin; Mattia Busana; Luciano Gattinoni; Federico Formenti
Journal:  Curr Opin Crit Care       Date:  2022-02-01       Impact factor: 3.687

8.  Correlation of lung collapse and gas exchange - a computer tomographic study in sheep and pigs with atelectasis in otherwise normal lungs.

Authors:  Samuel J Wolf; Alexander P Reske; Sören Hammermüller; Eduardo L V Costa; Peter M Spieth; Pierre Hepp; Alysson R Carvalho; Jens Kraßler; Hermann Wrigge; Marcelo B P Amato; Andreas W Reske
Journal:  PLoS One       Date:  2015-08-10       Impact factor: 3.240

9.  Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study.

Authors:  Davide Chiumello; Mattia Busana; Silvia Coppola; Federica Romitti; Paolo Formenti; Matteo Bonifazi; Tommaso Pozzi; Maria Michela Palumbo; Massimo Cressoni; Peter Herrmann; Konrad Meissner; Michael Quintel; Luigi Camporota; John J Marini; Luciano Gattinoni
Journal:  Intensive Care Med       Date:  2020-10-21       Impact factor: 17.440

  9 in total