A reliable and reproducible method for establishing accurate patella drill holes for quadriceps tendon repair.

A Dinneen1, J Clements, G Heilpern, G Railton.   

Abstract

Entities:  

Mesh:

Year:  2013        PMID: 23317738      PMCID: PMC3964649          DOI: 10.1308/rcsann.2013.76

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.951


× No keyword cloud information.

Background

Various techniques for quadriceps tendon repair have been described with biomechanical studies suggesting greater failure threshold with longitudinally placed drill holes. The current gold standard for repair uses 3–4 sutures passed through parallel longitudinal transpatellar bone tunnels. We describe a simple and reproducible technique for accurate placement of patella drill holes and passage of suture material.

Technique

Satisfactory hold is achieved in the quadriceps tendon with sutures. Using the Acufex® Director™ Drill Guide (Smith & Nephew, Andover, MA, US), the desired entry and exit locations for drill holes are selected on the patella (Fig 1). Three to four 2.4mm drill tip passing pins are placed (Fig 2). Each passing pin is then overdrilled with the 4.5mm ENDOBUTTON® (Smith & Nephew) cannulated drill bit. The free ends of suture are passed through the eyes of the 2.4mm drill tip passing pins (Fig 3) and pulled through the tunnels, exiting at the inferior pole (Fig 4). The repair can be tensioned as required before tying the suture ends at the inferior pole of the patella.
Figure 1

Acufex® Director™ Drill Guide positioned on patella

Figure 2

2.4mm drill tip passing pins through patella

Figure 3

Sutures passed through eyes of 2.4mm drill tip passing pins

Figure 4

Sutures pulled through patella tunnels to inferior pole

Acufex® Director™ Drill Guide positioned on patella 2.4mm drill tip passing pins through patella Sutures passed through eyes of 2.4mm drill tip passing pins Sutures pulled through patella tunnels to inferior pole

Discussion

The ability to drill parallel longitudinal transpatellar bone tunnels accurately freehand avoiding the articular surface while maintaining accurate exit points can pose a technical challenge. Coupled with difficulties encountered in passing the sutures through the tunnels, this can result in prolonged operative time with an associated increase in morbidity and needless frustration for the operating surgeon. The technique described here overcomes these difficulties while achieving gold standard repair.
  2 in total

1.  Suture anchor versus suture through tunnel fixation for quadriceps tendon rupture: a biomechanical study.

Authors:  William A Lighthart; David A Cohen; Richard G Levine; Brent G Parks; Henry R Boucher
Journal:  Orthopedics       Date:  2008-05       Impact factor: 1.390

2.  Primary repair of quadriceps tendon ruptures. Results of treatment.

Authors:  A T Rasul; D A Fischer
Journal:  Clin Orthop Relat Res       Date:  1993-04       Impact factor: 4.176

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.