Literature DB >> 23317147

Autologous canine red blood cell transfusion using cell salvage devices.

Lindsay M Kellett-Gregory1, Mayank Seth, Sophie Adamantos, Daniel L Chan.   

Abstract

OBJECTIVE: To describe the use of automated blood salvage devices for autotransfusion in dogs. TECHNIQUE: Blood salvage devices can be used to collect blood from the intraoperative surgical field or postsurgical drainage sites. The salvage device washes cells in 0.9% saline, removing plasma proteins, other cellular components, and activators of coagulation and inflammation. Washed red blood cells may be safely returned to the patient, minimizing the need for allogeneic blood transfusions. SIGNIFICANCE: Blood salvage has been safely used in human medicine for decades and is feasible in veterinary medicine. Potential advantages include reduced reliance on banked blood for massive transfusions and minimization of morbidities associated with the use of allogeneic and stored blood products. Concerns about the safety of salvaged blood have been largely dispelled in human medicine but further investigation regarding the safety of such procedures in veterinary patients is warranted. © Veterinary Emergency and Critical Care Society 2013.

Entities:  

Mesh:

Year:  2013        PMID: 23317147     DOI: 10.1111/vec.12017

Source DB:  PubMed          Journal:  J Vet Emerg Crit Care (San Antonio)        ISSN: 1476-4431


  3 in total

1.  Challenges in Perioperative Animal Care for Orthotopic Implantation of Tissue-Engineered Pulmonary Valves in the Ovine Model.

Authors:  Hussam Al Hussein; Hamida Al Hussein; Carmen Sircuta; Ovidiu S Cotoi; Ionela Movileanu; Dan Nistor; Bogdan Cordos; Radu Deac; Horatiu Suciu; Klara Brinzaniuc; Dan T Simionescu; Marius M Harpa
Journal:  Tissue Eng Regen Med       Date:  2020-08-29       Impact factor: 4.169

2.  Electrolyte and acid/base changes in dogs undergoing autologous blood transfusion via a cell salvage device.

Authors:  Jodie L Lamb; Kelley M Thieman Mankin; Gwendolyn J Levine; James Thompson
Journal:  Can Vet J       Date:  2015-09       Impact factor: 1.008

3.  A novel autotransfusion device saving erythrocytes and platelets used in a 72 h survival swine model of surgically induced controlled blood loss.

Authors:  Kévin Schreiber; Benoit Decouture; Audrey Lafragette; Stéphane Chollet; Marine Bruneau; Maxence Nicollet; Catherine Wittmann; Francis Gadrat; Alexandre Mansour; Patricia Forest-Villegas; Olivier Gauthier; Gwenola Touzot-Jourde
Journal:  PLoS One       Date:  2022-03-24       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.