Literature DB >> 23313302

Liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry as analytical tools to characterize multi-class cytostatic compounds.

Cristian Gómez-Canela1, Nuria Cortés-Francisco, Francesc Ventura, Josep Caixach, Silvia Lacorte.   

Abstract

Cytostatic compounds used in the treatment of cancer have emerged as a new generation of water contaminants due to the continuous amounts administered to patients and to the fact that a variable proportion is excreted unchanged. In this study, we have evaluated the performance of liquid-chromatography-tandem mass spectrometry (LC-MS/MS) and high resolution mass spectrometry using an Orbitrap analyzer (LC-HRMS) for the multiresidue determination of multi-class cytostatic compounds. In a first step, ionization conditions were tested in positive electrospray mode and optimum fragmentation patterns were determined. For LC-MS/MS, two selected reaction monitoring (SRM) transitions were optimized and for LC-HRMS, the molecular ion with 5 ppm error and two product ions were defined. Following, the chromatographic conditions were optimized considering that compounds analyzed have a very different chemical structure and chromatographic behavior. The best performance was obtained with a Luna C18 column, which permitted the separation of the 26 compounds in 15 min. Finally, the performance of LC-MS/MS and LC-HRMS was compared in terms of linearity, sensitivity, intra and inter-day precision and overall robustness. While LC-MS/MS provided good identification capabilities due to selective SRM transitions, LC-Orbitrap proved to be 100 times more sensitive. This study provides a comprehensive overview on the MS conditions to determine the outmost used cytostatic compounds and provides a spectral library to be used for the identification of these compounds in water or biological matrices.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23313302     DOI: 10.1016/j.chroma.2012.12.031

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Determination of cytostatic drugs in Besòs River (NE Spain) and comparison with predicted environmental concentrations.

Authors:  Helena Franquet-Griell; Deborah Cornadó; Josep Caixach; Francesc Ventura; Silvia Lacorte
Journal:  Environ Sci Pollut Res Int       Date:  2017-01-10       Impact factor: 4.223

2.  Fabrication of an electrochemical sensor for determination of doxorubicin in human plasma and its interaction with DNA.

Authors:  Reza Hajian; Zahra Tayebi; Nafiseh Shams
Journal:  J Pharm Anal       Date:  2016-07-19

3.  Targeted metabolomics of Gammarus pulex following controlled exposures to selected pharmaceuticals in water.

Authors:  Cristian Gómez-Canela; Thomas H Miller; Nicolas R Bury; Romà Tauler; Leon P Barron
Journal:  Sci Total Environ       Date:  2016-04-22       Impact factor: 7.963

Review 4.  Occurrence of anticancer drugs in the aquatic environment: a systematic review.

Authors:  Carla Nassour; Stephen J Barton; Shereen Nabhani-Gebara; Yolande Saab; James Barker
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-12       Impact factor: 4.223

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.