Literature DB >> 23307101

Emission characteristics of VOCs from three fixed-roof p-xylene liquid storage tanks.

Chungsying Lu1, Hsiaoyun Huang, Shenteng Chang, Shihchieh Hsu.   

Abstract

This study evaluates emission characteristics of volatile organic compounds (VOCs) caused by standing loss (L S) and working loss (L W) of three vertical fixed-roof p-xylene (p-X) liquid tanks during 1-year storage and filling operation. The annual net throughput of the tanks reached 70,446 t, resulting in 9,425 kg of p-X vapor emission including 5,046 kg of L S (53.54 %) and 4,379 kg of L W (46.46 %). The estimated L W of AP-42 displayed better agreement with the measured values of a VOC detector than the estimated L S of AP-42. The L S was best correlated with the liquid height of the tanks, while the L W was best correlated with the net throughput of the tanks. As a result, decreasing vapor space volume of the tanks and avoiding high net throughput of the tanks in a high ambient temperature period were considered as effective means to lessen VOC emission from the fixed-roof organic liquid storage tank.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23307101     DOI: 10.1007/s10661-013-3067-9

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  3 in total

1.  Treatment of waste gas from the breather vent of a vertical fixed roof p-xylene storage tank by a trickle-bed air biofilter.

Authors:  Shenteng Chang; Chungsying Lu; Shihchieh Hsu; How-Tsan Lai; Wen-Lin Shang; Yeong-Song Chuang; Chi-Huang Cho; Sheng-Han Chen
Journal:  Bioresour Technol       Date:  2010-10-28       Impact factor: 9.642

2.  Monitoring of hydrocarbon emissions in a petroleum refinery.

Authors:  Padma Rao; S Ankam; M Ansari; A G Gavane; A Kumar; V I Pandit; P Nema
Journal:  Environ Monit Assess       Date:  2005-09       Impact factor: 2.513

3.  Organic liquids storage tanks volatile organic compounds (VOCS) emissions dispersion and risk assessment in developing countries: the case of Dar-es-Salaam City, Tanzania.

Authors:  Msafiri M Jackson
Journal:  Environ Monit Assess       Date:  2006-05       Impact factor: 2.513

  3 in total
  1 in total

1.  Emission losses and dispersion of volatile organic compounds from tank farm of petroleum refinery complex.

Authors:  Suwadi Saikomol; Sarawut Thepanondh; Wanna Laowagul
Journal:  J Environ Health Sci Eng       Date:  2019-03-30
  1 in total