Literature DB >> 23306407

Bubble CPAP versus ventilator CPAP in preterm neonates with early onset respiratory distress--a randomized controlled trial.

Amit Tagare1, Sandeep Kadam, Umesh Vaidya, Anand Pandit, Sanjay Patole.   

Abstract

UNLABELLED: Bubble continuous positive airway pressure (BCPAP) is a low cost nasal CPAP delivery system with potential benefits to developing nations.
OBJECTIVE: To compare the efficacy and safety of BCPAP with ventilator-derived CPAP (VCPAP) in preterm neonates with respiratory distress.
METHODS: In a randomized controlled trial, preterm neonates with Silverman-Anderson score ≥ 4 and oxygen requirement >30% within first 6 h of life were randomly allocated to BCPAP or VCPAP. Proportion of neonates with success or failure was compared.
RESULTS: In all, 47 of 57 (82.5%) neonates from BCPAP group and 36 of 57 (63.2%) neonates from the VCPAP group completed CPAP successfully (p = 0.03). Neonates who failed CPAP had higher Silverman-Anderson score (p < 0.01), lower arterial to alveolar oxygenation ratio (p < 0.05) and needed surfactant more frequently (p < 0.01).
CONCLUSION: BCPAP has higher success rate than VCPAP for managing preterm neonates with early onset respiratory distress, with comparable safety.

Entities:  

Mesh:

Year:  2013        PMID: 23306407     DOI: 10.1093/tropej/fms061

Source DB:  PubMed          Journal:  J Trop Pediatr        ISSN: 0142-6338            Impact factor:   1.165


  13 in total

1.  A Randomized Trial Comparing Efficacy of Bubble and Ventilator Derived Nasal CPAP in Very Low Birth Weight Neonates with Respiratory Distress.

Authors:  Sheetal Agarwal; Arti Maria; Mahesh K Roy; Ankit Verma
Journal:  J Clin Diagn Res       Date:  2016-09-01

2.  Use of Nasal Bubble CPAP in Children with Hypoxemic Clinical Pneumonia-Report from a Resource Limited Set-Up.

Authors:  Muralidharan Jayashree; H B KiranBabu; Sunit Singhi; Karthi Nallasamy
Journal:  J Trop Pediatr       Date:  2015-09-30       Impact factor: 1.165

Review 3.  Preventing Continuous Positive Airway Pressure Failure: Evidence-Based and Physiologically Sound Practices from Delivery Room to the Neonatal Intensive Care Unit.

Authors:  Clyde J Wright; Laurie G Sherlock; Rakesh Sahni; Richard A Polin
Journal:  Clin Perinatol       Date:  2018-02-28       Impact factor: 3.430

4.  Impact of the systematic introduction of low-cost bubble nasal CPAP in a NICU of a developing country: a prospective pre- and post-intervention study.

Authors:  Rossano Rezzonico; Letizia M Caccamo; Valeria Manfredini; Massimo Cartabia; Nieves Sanchez; Zoraida Paredes; Patrizia Froesch; Franco Cavalli; Maurizio Bonati
Journal:  BMC Pediatr       Date:  2015-03-25       Impact factor: 2.125

5.  Short term evaluation of respiratory effort by premature infants supported with bubble nasal continuous airway pressure using Seattle-PAP and a standard bubble device.

Authors:  Stephen E Welty; Craig G Rusin; Larissa I Stanberry; George T Mandy; Alfred L Gest; Jeremy M Ford; Carl H Backes; C Peter Richardson; Christopher R Howard; Thomas N Hansen; Charles V Smith
Journal:  PLoS One       Date:  2018-03-28       Impact factor: 3.240

Review 6.  Non-invasive Respiratory Support of the Premature Neonate: From Physics to Bench to Practice.

Authors:  Ibrahim Sammour; Sreenivas Karnati
Journal:  Front Pediatr       Date:  2020-05-08       Impact factor: 3.418

7.  Treatment outcomes of Pumani bubble-CPAP versus oxygen therapy among preterm babies presenting with respiratory distress at a tertiary hospital in Tanzania-Randomised trial.

Authors:  Annette Baine Mwatha; Michael Mahande; Raimos Olomi; Beatrice John; Rune Philemon
Journal:  PLoS One       Date:  2020-06-30       Impact factor: 3.240

8.  Decreasing Chronic Lung Disease Associated with Bubble CPAP Technology: Experience at Five Years.

Authors:  Tricia A Miller; Jing Li; Stella Riddell; Steven C Barkley
Journal:  Pediatr Qual Saf       Date:  2020-04-10

9.  Improving Respiratory Support Practices to Reduce Chronic Lung Disease in Premature Infants.

Authors:  Bernadette M Levesque; Laura Burnham; Natasha Cardoza; Marsha Adams; Robyn Cohen; Mark Mirochnick; Alan Fujii; Bharati Sinha
Journal:  Pediatr Qual Saf       Date:  2019-08-09

10.  Use of a modified bubble continuous positive airway pressure (bCPAP) device for children in respiratory distress in low- and middle-income countries: a safety study.

Authors:  Ashley R Bjorklund; Beatrice Odongkara Mpora; Marie E Steiner; Gwenyth Fischer; Cynthia S Davey; Tina M Slusher
Journal:  Paediatr Int Child Health       Date:  2018-06-18       Impact factor: 1.990

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.