Literature DB >> 23305986

A comparison between the technical absorbent and ventilated capsule methods for measuring local sweat rate.

Nathan B Morris1, Matthew N Cramer, Simon G Hodder, George Havenith, Ollie Jay.   

Abstract

This study assessed the accuracy of the technical absorbent (TA) method for measuring local sweat rate (LSR) relative to the well-established ventilated capsule (VC) method during steady-state and nonsteady-state sweating using large and small sample surface areas on the forearm and midback. Forty participants (38 males and two females) cycled at 60% peak oxygen consumption for 75 min in either a temperate [22.3 ± 0.9°C, 32 ± 17% relative humidity (RH)] or warm (32.5 ± 0.8°C, 29 ± 7% RH) environment. Simultaneous bilateral comparisons of 5-min LSR measurements using the TA and VC methods were performed for the back and forearm after 10, 30, 50, and 70 min. LSR values, measured using the TA method, were highly correlated with the VC method at all time points, irrespective of sample surface area and body region (all P < 0.001). On average, ≈ 79% of the variability observed in LSR measured with the VC method was described by the TA method. The mean difference in absolute LSR using the TA method (TA-VC with 95% confidence intervals) was -0.23 [-0.30,-0.16], -0.11 [-0.21,0.00], -0.03 [-0.14,+0.08], and +0.02 [-0.07,+0.11] mg · cm(-2) · min(-1) after 10, 30, 50, and 70 min of exercise, respectively. Duplicate LSR measurements within each method during steady-state sweating were highly correlated (TA: r = 0.96, P < 0.001, n = 20; VC: r = 0.97, P < 0.001, n = 20) with a mean bias of +0.07 ± 0.14 and +0.01 ± 0.10 mg · cm(-2) · min(-1) for TA and VC methods, respectively. The mean smallest detectable difference in LSR was 0.12 and 0.05 mg · min(-1) · cm(-2) for TA and VC methods, respectively. These data support the TA method as a reliable alternative for measuring the rate of sweat appearance on the skin surface.

Entities:  

Mesh:

Year:  2013        PMID: 23305986     DOI: 10.1152/japplphysiol.01088.2012

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  18 in total

1.  Explained variance in the thermoregulatory responses to exercise: the independent roles of biophysical and fitness/fatness-related factors.

Authors:  Matthew N Cramer; Ollie Jay
Journal:  J Appl Physiol (1985)       Date:  2015-08-27

2.  On exercise thermoregulation in females: interaction of endogenous and exogenous ovarian hormones.

Authors:  Tze-Huan Lei; James D Cotter; Zachary J Schlader; Stephen R Stannard; Blake G Perry; Matthew J Barnes; Toby Mündel
Journal:  J Physiol       Date:  2018-11-22       Impact factor: 5.182

3.  The effect of hot and cold drinks on thermoregulation, perception, and performance: the role of the gut in thermoreception.

Authors:  Martin J Barwood; Stuart Goodall; Jon Bateman
Journal:  Eur J Appl Physiol       Date:  2018-09-10       Impact factor: 3.078

4.  Sunscreen Use and Sweat Production in Men and Women.

Authors:  Jorge Aburto-Corona; Luis Aragón-Vargas
Journal:  J Athl Train       Date:  2016-10-14       Impact factor: 2.860

5.  No Thermoregulatory Impairment in Skin Graft Donor Sites during Exercise-Heat Stress.

Authors:  Matthew N Cramer; Gilbert Moralez; M U Huang; Craig G Crandall
Journal:  Med Sci Sports Exerc       Date:  2019-05       Impact factor: 5.411

Review 6.  Human temperature regulation under heat stress in health, disease, and injury.

Authors:  Matthew N Cramer; Daniel Gagnon; Orlando Laitano; Craig G Crandall
Journal:  Physiol Rev       Date:  2022-06-09       Impact factor: 46.500

7.  Low-Cost Wearable Fluidic Sweat Collection Patch for Continuous Analyte Monitoring and Offline Analysis.

Authors:  Annemarijn S M Steijlen; Kaspar M B Jansen; Jeroen Bastemeijer; Paddy J French; Andre Bossche
Journal:  Anal Chem       Date:  2022-04-29       Impact factor: 8.008

Review 8.  Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

Authors:  Lindsay B Baker
Journal:  Sports Med       Date:  2017-03       Impact factor: 11.136

9.  A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring.

Authors:  Andrew Brueck; Tashfin Iftekhar; Alicja B Stannard; Kumar Yelamarthi; Tolga Kaya
Journal:  Sensors (Basel)       Date:  2018-02-10       Impact factor: 3.576

10.  Free-living, continuous hypo-hydration, and cardiovascular response to exercise in a heated environment.

Authors:  Kate S Early; Conrad P Earnest; Bailey Theall; Nathan P Lemoine; Brian Harrell; Neil M Johannsen
Journal:  Physiol Rep       Date:  2018-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.