Literature DB >> 23305117

Non-Severinghaus potentiometric dissolved CO2 sensor with improved characteristics.

Xiaojiang Xie1, Eric Bakker.   

Abstract

A new type of carbon dioxide sensor comprising a pH glass electrode measured against a carbonate-selective membrane electrode based on a tweezer type carbonate ionophore is presented here for the first time. No cumbersome liquid junction based reference element is utilized in this measurement. The sensor shows an expected nernstian divalent response slope to dissolved CO(2) over a wide range covering the routine environmental and physiological PCO(2) levels. Unlike the conventional Severinghaus CO(2) probe for which the response is substantially delayed to up to 10 min due to diffusion of carbon dioxide into the internal compartment, the ion-selective CO(2) sensor proposed here shows a response time (t(95%)) of 5 s. When used together with a traditional reference electrode, the sensor system is confirmed to also monitor sample pH and carbonate along with carbon dioxide. A selectivity analysis suggests that Cl(-) does not interfere even at high concentrations, allowing one to explore this type of sensor probe for use in seawater or undiluted blood samples. The CO(2) probe has been used in an aquarium to monitor the CO(2) levels caused by the diurnal cycles caused by the metabolism of the aquatic plants and shows stable and reproducible results.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23305117     DOI: 10.1021/ac303534v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

2.  A New Application of Internet of Things and Cloud Services in Analytical Chemistry: Determination of Bicarbonate in Water.

Authors:  J V Capella; Alberto Bonastre; Rafael Ors; Miguel Peris
Journal:  Sensors (Basel)       Date:  2019-12-14       Impact factor: 3.576

3.  Potentiometric detection of chemical vapors using molecularly imprinted polymers as receptors.

Authors:  Rongning Liang; Lusi Chen; Wei Qin
Journal:  Sci Rep       Date:  2015-07-28       Impact factor: 4.379

4.  Nanostructured Gas Sensors for Health Care: An Overview.

Authors:  Ajeet Kaushik; Rajesh Kumar; Rahul Dev Jayant; Madhavan Nair
Journal:  J Pers Nanomed       Date:  2015-07-27

5.  Anion-activated, thermoreversible gelation system for the capture, release, and visual monitoring of CO2.

Authors:  Xin Zhang; Songyi Lee; Yifan Liu; Minji Lee; Jun Yin; Jonathan L Sessler; Juyoung Yoon
Journal:  Sci Rep       Date:  2014-04-04       Impact factor: 4.379

Review 6.  Ion Selective Amperometric Biosensors for Environmental Analysis of Nitrate, Nitrite and Sulfate.

Authors:  Niels Peter Revsbech; Michael Nielsen; Deby Fapyane
Journal:  Sensors (Basel)       Date:  2020-08-03       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.