Literature DB >> 23304975

Correction of severe tooth rotations using clear aligners: a case report.

Gianluigi Frongia1, Tommaso Castroflorio.   

Abstract

BACKGROUND: The present adult patient case report shows the correction of a crossbite malocclusion and severe tooth rotations treated with the Invisalign system.
METHODS: A 27-year-old female with a dental crossbite (24, 34), severe rotations of two lower incisors (more than 40 degrees) and malalignment of the upper and lower arches is described. The Invisalign system was treatment planned to correct the malocclusion.
RESULTS: The treatment goals of crossbite, rotation and malalignment correction were achieved after 12 months of active aligner therapy. The overbite improved (2.5 mm before treatment, 1 mm at the end); the dental crossbite, the crowding and the severe tooth rotations (with a mean of 2 degrees of improvement per aligner) were corrected.
CONCLUSIONS: After treatment, the dental alignment was considered excellent. The presented case indicates that the Invisalign system can be a useful appliance to correct a dental malocclusion involving severe rotations.

Entities:  

Mesh:

Year:  2012        PMID: 23304975

Source DB:  PubMed          Journal:  Aust Orthod J        ISSN: 0587-3908


  5 in total

1.  Upper arch dimensional changes with clear aligners in the early mixed dentition : A prospective study.

Authors:  Roberta Lione; Elisabetta Cretella Lombardo; Valeria Paoloni; Simonetta Meuli; Chiara Pavoni; Paola Cozza
Journal:  J Orofac Orthop       Date:  2021-09-03       Impact factor: 1.938

2.  Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor.

Authors:  Xiaowei Li; Chaochao Ren; Zheyao Wang; Pai Zhao; Hongmei Wang; Yuxing Bai
Journal:  Korean J Orthod       Date:  2016-03-18       Impact factor: 1.372

3.  A comparison of treatment effectiveness between clear aligner and fixed appliance therapies.

Authors:  Yunyan Ke; Yanfei Zhu; Min Zhu
Journal:  BMC Oral Health       Date:  2019-01-23       Impact factor: 2.757

4.  Does Clear Aligner Treatment Result in Different Patient Perceptions of Treatment Process and Outcomes Compared to Conventional/Traditional Fixed Appliance Treatment: A Literature Review.

Authors:  Afnan A Ben Gassem
Journal:  Eur J Dent       Date:  2021-12-22

5.  Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study.

Authors:  Sayuri Inoue; Satoshi Yamaguchi; Hiroshi Uyama; Takashi Yamashiro; Satoshi Imazato
Journal:  Materials (Basel)       Date:  2020-09-14       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.