The effect of sliding knots on the suture-tendon interface strength: a biomechanical analysis comparing sliding and static arthroscopic knots.

Albert J Savage1, Murray D Spruiell, Joseph M Schwertz, Gerald McGwin, Alan Eberhardt, Brent A Ponce.   

Abstract

BACKGROUND: The tissue-suture interface remains the most common site of failure in rotator cuff repairs. It is currently unknown if arthroscopic sliding knots injure the tissue and weaken the suture-tendon interface.
PURPOSE: To evaluate the effect sliding knots have on the strength of the suture-tendon interface. STUDY
DESIGN: Controlled laboratory study.
METHODS: A total of 32 sheep infraspinatus tendons were randomized among 4 groups of stitches (n = 8): simple-static, simple-sliding, mattress-static, and mattress-sliding. All high-strength, No. 2 suture stitch-knot combinations were created in an arthroscopic simulated environment, and sliding knots were tied with shortening of the suture and sliding of the knot down to the tissue interface to simulate surgical technique. Each graft was cyclically loaded on a mechanical testing system from 5 to 20 N for 20 cycles and then loaded to failure. A least squares analysis of variance model was used to test significance of sliding stitches upon cyclic elongation, peak-to-peak displacement, and ultimate load. Estimated means and standard deviations are reported from the regression model.
RESULTS: A mattress-static stitch (116 N) was significantly stronger than a mattress-sliding stitch (70 N; P < .001). The ultimate loads for the simple-static (46 N) and sliding (50 N) stitches were not statistically different. For cyclic elongation, the only difference was the mattress-sliding stitch (0.95 mm) having a greater elongation than the simple-static (0.61 mm; P = .01) and simple-sliding (0.68 mm; P = .04) stitches. Both mattress stitches had significantly less peak-to-peak displacement (0.39 and 0.41 mm) than the simple stitches (0.47 and 0.46 mm; P < .001).
CONCLUSION: Sliding suture through tissue weakens the suture-tendon interface in mattress stitch constructs but not in simple stitch constructs. Mattress stitches have superior holding strength compared with simple stitches. CLINICAL RELEVANCE: Clinical relevance is uncertain. In situations with poor tissue quality or concern regarding tension across the repair, consideration should be given to using static knots as opposed to sliding knots when placing mattress stitches.

Entities:  

Mesh:

Year:  2013        PMID: 23299852     DOI: 10.1177/0363546512472168

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  4 in total

1.  Biomechanical analysis of the interval slide procedure: a fresh porcine cadaver study.

Authors:  Felix Porschke; Marc Schnetzke; Christoph Luecke; Christel Weiss; Stefan Studier-Fischer; Paul Alfred Gruetzner; Thorsten Guehring
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-21       Impact factor: 2.928

Review 2.  The role of animal models in tendon research.

Authors:  M W Hast; A Zuskov; L J Soslowsky
Journal:  Bone Joint Res       Date:  2014-06       Impact factor: 5.853

Review 3.  Sliding or Nonsliding Arthroscopic Knots for Shoulder Surgery: A Systematic Review.

Authors:  Caellagh D Morrissey; Darby A Houck; Esther Jang; Eric C McCarty; Jonathan T Bravman; Adam J Seidl; Michelle L Wolcott; Armando F Vidal; Rachel M Frank
Journal:  Orthop J Sports Med       Date:  2020-04-24

4.  Comparison of arthroscopic single-row and double-row repair in the treatment of rotator cuff tears: A protocol of cohort analysis.

Authors:  Yanming Lin; Jiasong Zhao; Heng Qiu; Yong Huang
Journal:  Medicine (Baltimore)       Date:  2020-07-17       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.