Literature DB >> 23298783

Influence of tool geometry on drilling performance of cortical and trabecular bone.

G J M Tuijthof1, C Frühwirt, C Kment.   

Abstract

Minimally invasive surgery poses high demands on tool design. The goal was to measure the influence of drill bit geometry on maximum thrust forces required for drilling, and compare this relative to the known influence of feed rate and bone composition. Blind holes were drilled perpendicular to the iliac crest up to 10 mm depth in cadaveric pelvic bones of 20 pigs (adolescent) and 11 goats (full grown) with eight substantially different drill bits of ∅ 3-3.2 mm. Subsequently, boreholes were drilled perpendicular to the ilium with the same drill bits at three different feed rates (0.58 mm/s, 0.83 mm/s, 1.08 mm/s). The mean maximum thrust force ranges from 10 to 110 N for cortical bone, and from 3 to 65 N for trabecular bone. The results show that both drill bit geometry and feed rate have a significant influence on the maximum thrust forces, with a dominant influence of drill bit geometry in terms of shape of the flutes, sharpness of cutting edges and value of point angle. The differences in thrust forces between cortical and trabecular bone are substantial for all measured conditions. The measured values can be used for drill design.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23298783     DOI: 10.1016/j.medengphy.2012.12.004

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

2.  A predictive bone drilling force model for haptic rendering with experimental validation using fresh cadaveric bone.

Authors:  Yanping Lin; Huajiang Chen; Dedong Yu; Ying Zhang; Wen Yuan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-22       Impact factor: 2.924

Review 3.  Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review.

Authors:  Mohd Faizal Ali Akhbar; Akmal Wani Sulong
Journal:  Ann Biomed Eng       Date:  2020-08-28       Impact factor: 3.934

4.  Biophysical regulation of osteotomy healing: An animal study.

Authors:  Liao Wang; Maziar Aghvami; John Brunski; Jill Helms
Journal:  Clin Implant Dent Relat Res       Date:  2017-06-13       Impact factor: 3.932

5.  Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study.

Authors:  Mohammad Javad Ein-Afshar; Mostafa Shahrezaee; Mohammad Hossein Shahrezaee; Seyed Reza Sharifzadeh
Journal:  Arch Bone Jt Surg       Date:  2020-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.