Literature DB >> 23297849

In vivo evaluation of occlusalcontact area and maximum bite force in patients with various types of implant-supported prostheses.

Emrah Baca1, Esengn Yengin, Bılge Gökçen-Röhlig, Suichi Sato.   

Abstract

OBJECTIVE: To determine the effects of various implant retained and/or supported prostheses on number of occlusal contacts (NOC), occlusal contact area (OCA)and maximum bite force (BF). PATIENTS AND METHODS: In total, 56 patients were included in the study; five test groups and two control groups. The patients in the treatment groups received implant-supported/retained prosthesis; over-dentures retained with two individual attachments in occlusion with complete denture, with four individual attachments in occlusion with complete denture, with four individual attachments in occlusion with fixed partial dentures or natural dentition, 6-implant retained fixed bridges in occlusion with natural dentition and 8-implant retained fixed bridges in occlusion with natural dentition. The patients in control group 1 were wearing conventional complete maxillary and mandibular dentures, whereas in control group 2 they had fixed full-arch porcelain-fused to metal restorations prostheses for both arches. Dental Pre-scale was used measure the NOC, BF and OCA.
RESULTS: There was no statistically significant difference between the treatment and control groups, among the groups with regards to NOC. OCA demonstrated different results among the removable and fixed reconstruction groups. With regards to BF, removable dentures supported with four implants showed higher bite force values than controls and two implant over-dentures. Also, a fixed reconstruction using eight implants showed higher BF values than a fixed reconstruction using six implants.
CONCLUSION: Use of implants for removable dentures and fixed reconstructions improve occlusal contact area and bite force.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23297849     DOI: 10.3109/00016357.2012.757360

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  2 in total

1.  Influence of dental implantation on bone mineral density distribution: a pilot study.

Authors:  Damian Jae-Whan Lee; Eun-Sang Moon; Kenneth Stephen; Jie Liu; Do-Gyoon Kim
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

2.  Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis.

Authors:  Ana Paula Barbosa Lima; Rafael Pino Vitti; Marina Amaral; Ana Christina Claro Neves; Lais Regiane da Silva Concilio
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.