Literature DB >> 23297834

The use of high frequency ultrasound imaging in skin moisturization measurement.

Robert K Mlosek1, Sylwia Malinowska, Magdalena Sikora, Renata Dębowska, Anna Stępień, Karolina Czekaj, Anna Dąbrowska.   

Abstract

INTRODUCTION: The appropriate skin hydration level enables its normal function and healthy appearance.
PURPOSE: The purpose of present research was to assess the applicability of high frequency ultrasound (HFU) to the monitoring of skin moisturization treatments.
MATERIAL AND METHODS: The study sample encompassed 27 women, aged 20-67 y.o. (mean age of 45.48 y.o.) with dry skin. All women applied a strong moisturizing cream on their facial skin for 14 days. The course of treatment was monitored using the HFU. The following parameters were subjected to the ultrasound evaluation: epidermal echo thickness, dermis thickness, and separately the thickness of the superior and inferior layer of dermis. The measurements were taken on the participants' chins and cheeks. In addition, skin hydration and transepidermal water loss (TEWL) were determined.
RESULTS: Statistically significant differences were obtained between the echogenicity of the superior layer of the dermis on the chin and cheek. After treatment, the statistically significant values of TEWL decrease and hydration increase were obtained on the cheek skin. No statistically significant differences between the TEWL or hydration levels were found on the chin. No statistically significant differences between the epidermal echo and dermis thickness values for the two measurement points were observed.
CONCLUSION: The HFU is a useful method for the monitoring of skin moisturization treatments.
© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23297834     DOI: 10.1111/srt.12029

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  6 in total

Review 1.  Emerging Technologies to Target Drug Delivery to the Skin - the Role of Crystals and Carrier-Based Systems in the Case Study of Dapsone.

Authors:  Gabriela Schneider-Rauber; Debora Fretes Argenta; Thiago Caon
Journal:  Pharm Res       Date:  2020-11-09       Impact factor: 4.200

2.  High-Frequency Ultrasound: Description of Sacral Tissue Characteristics in Healthy Adults.

Authors:  Ruth S Burk; Christine M Schubert; Anathea Pepperl; Mary Jo Grap
Journal:  J Wound Ostomy Continence Nurs       Date:  2017 Sep/Oct       Impact factor: 1.741

Review 3.  Modern non-invasive diagnostic techniques in the detection of early cutaneous melanoma.

Authors:  Agnieszka Kardynal; Malgorzata Olszewska
Journal:  J Dermatol Case Rep       Date:  2014-03-31

4.  A study of the activity and effectiveness of recombinant fibroblast growth factor (Q40P/S47I/H93G rFGF-1) in anti-aging treatment.

Authors:  Justyna Żerańska; Monika Pasikowska; Barbara Szczepanik; Krzysztof Mlosek; Sylwia Malinowska; Renata M Dębowska; Irena Eris
Journal:  Postepy Dermatol Alergol       Date:  2016-02-29       Impact factor: 1.837

5.  The use of high-frequency ultrasonography in the assessment of selected female reproductive structures: the vulva, vagina and cervix.

Authors:  Marian Stanisław Migda; Michał Migda; Rafał Słapa; Robert Krzysztof Mlosek; Bartosz Migda
Journal:  J Ultrason       Date:  2019-12-31

6.  Effects of loading and prophylactic dressings on the sacral and heel skin: An exploratory cross-over trial.

Authors:  Andrea Lichterfeld-Kottner; Annika Vogt; Tsenka Tomova-Simitchieva; Ulrike Blume-Peytavi; Jan Kottner
Journal:  Int Wound J       Date:  2021-05-03       Impact factor: 3.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.