Literature DB >> 2329481

Theoretical versus SRK I and SRK II calculation of intraocular lens power.

T Olsen1, K Thim, L Corydon.   

Abstract

The predictability of a theoretical, computerized (PC-assisted) intraocular lens (IOL) power calculation method and of the Sanders-Retzlaff-Kraff [SRK] I and II methods was evaluated from preoperative and postoperative biometry in 202 cataractous patients who had extracapsular cataract extraction (ECCE). The theoretical method resulted in the lowest range and standard deviation of the error, and the highest correlation coefficient between the observed and the predicted refraction (P less than .05). The superiority of the theoretical approach was most clearly demonstrated when the postoperative measurements were used in the predictions (P less than .001). This demonstrated the potential accuracy of the formula used and the importance of incorporating methods to predict the IOL position after surgery. If the prediction of the IOL chamber depth was properly corrected for the axial length dependence, a high prediction accuracy could be obtained in short as well as in long eyes.

Entities:  

Mesh:

Year:  1990        PMID: 2329481     DOI: 10.1016/s0886-3350(13)80734-1

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Long-term influence of insulin dependent diabetes mellitus on refraction and its components: a population based twin study.

Authors:  N Løgstrup; A K Sjølie; K O Kyvik; A Green
Journal:  Br J Ophthalmol       Date:  1997-05       Impact factor: 4.638

2.  [Individualization of IOL constants for two hydrophobic intraocular lenses. SRK II, SRK/T, Hoffer-Q, Holladay 1 and Haigis formula].

Authors:  A Langenbucher; T Eppig; A Viestenz; B Seitz; G Müllner; U Schönherr
Journal:  Ophthalmologe       Date:  2012-05       Impact factor: 1.059

3.  IOL Formula Constants: Strategies for Optimization and Defining Standards for Presenting Data.

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Michael Müller; Timo Eppig; Simon Schröder; Ekkehart Fabian
Journal:  Ophthalmic Res       Date:  2021-02-02       Impact factor: 2.892

4.  Measurement of optic disc size: equivalence of methods to correct for ocular magnification.

Authors:  D F Garway-Heath; A R Rudnicka; T Lowe; P J Foster; F W Fitzke; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 5.908

5.  Improvement of Multiple Generations of Intraocular Lens Calculation Formulae with a Novel Approach Using Artificial Intelligence.

Authors:  John Ladas; Donna Ladas; Shawn R Lin; Uday Devgan; Aazim A Siddiqui; Albert S Jun
Journal:  Transl Vis Sci Technol       Date:  2021-03-01       Impact factor: 3.283

6.  Full OCT anterior segment biometry: an application in cataract surgery.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Sonia Durán; Miriam Velasco-Ocana; Judith Birkenfeld; Alberto de Castro; Ignacio Jiménez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2013-01-31       Impact factor: 3.732

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.