Literature DB >> 23294588

Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique.

Kai Sun1, Guo-Rong Liu, Yue-Chun Li, Rui-Juan Han, Li-Fang Cui, Li-Jun Ma, Li-Gang Li, Chang-Yong Li.   

Abstract

Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv, P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.

Entities:  

Mesh:

Year:  2013        PMID: 23294588     DOI: 10.1016/s1001-9294(13)60006-1

Source DB:  PubMed          Journal:  Chin Med Sci J        ISSN: 1001-9294


  2 in total

1.  Comparison of sequential and high-pitch-spiral coronary CT-angiography: image quality and radiation exposure.

Authors:  D Seppelt; C Kolb; J P Kühn; U Speiser; C G Radosa; S Hoberück; R T Hoffmann; I Platzek
Journal:  Int J Cardiovasc Imaging       Date:  2019-03-08       Impact factor: 2.357

2.  A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan.

Authors:  Cheng-Chih Hsieh; An-Bang Zeng; Chia-Hung Chen; Zong-Yi Jhou; Chih-Hsin Wang; Ya-Ling Yang; Feng-Chuan Hsieh; Jing-Kai Lin; Ju-Yen Yeh; Chun-Chao Huang
Journal:  BMC Med Imaging       Date:  2021-10-30       Impact factor: 1.930

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.