Literature DB >> 23289874

Digital implant impressions with the "Individualized Scanbody Technique" for emergence profile support.

Tim Joda1,2, Julia-Gabriela Wittneben1, Urs Brägger1.   

Abstract

OBJECTIVE: The Short Communication presents a clinical case in which a novel procedure--the "Individualized Scanbody Technique" (IST)--was applied, starting with an intraoral digital impression and using CAD/CAM process for fabrication of ceramic reconstructions in bone level implants.
MATERIAL AND METHODS: A standardized scanbody was individually modified in accordance with the created emergence profile of the provisional implant-supported restoration. Due to the specific adaptation of the scanbody, the conditioned supra-implant soft tissue complex was stabilized for the intraoral optical scan process. Then, the implant platform position and the supra-implant mucosa outline were transferred into the three-dimensional data set with a digital impression system. Within the technical workflow, the ZrO2 -implant-abutment substructure could be designed virtually with predictable margins of the supra-implant mucosa.
RESULTS: After finalization of the 1-piece screw-retained full ceramic implant crown, the restoration demonstrated an appealing treatment outcome with harmonious soft tissue architecture.
CONCLUSIONS: The IST facilitates a simple and fast approach for a supra-implant mucosal outline transfer in the digital workflow. Moreover, the IST closes the interfaces in the full digital pathway.
© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Keywords:  dental implant; digital impression; emergence profile; esthetics; intraoral optical scan; scanbody

Mesh:

Year:  2013        PMID: 23289874     DOI: 10.1111/clr.12099

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  From Guided Surgery to Final Prosthesis with a Fully Digital Procedure: A Prospective Clinical Study on 15 Partially Edentulous Patients.

Authors:  Giorgio Andrea Dolcini; Marco Colombo; Carlo Mangano
Journal:  Int J Dent       Date:  2016-07-14

Review 2.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

3.  Accuracy of Implant Casts Generated with Conventional and Digital Impressions-An In Vitro Study.

Authors:  Paulo Ribeiro; Mariano Herrero-Climent; Carmen Díaz-Castro; José Vicente Ríos-Santos; Roberto Padrós; Javier Gil Mur; Carlos Falcão
Journal:  Int J Environ Res Public Health       Date:  2018-07-27       Impact factor: 3.390

Review 4.  Digital Impressions in Implant Dentistry: A Literature Review.

Authors:  Simone Marques; Paulo Ribeiro; Carlos Falcão; Bernardo Ferreira Lemos; Blanca Ríos-Carrasco; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-24       Impact factor: 3.390

5.  In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants.

Authors:  Reiji Natsubori; Shota Fukazawa; Toyokazu Chiba; Norimasa Tanabe; Hidemichi Kihara; Hisatomo Kondo
Journal:  Int J Implant Dent       Date:  2022-04-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.