Literature DB >> 23280982

Use of modified Doehlert-type experimental design in optimization of a hybrid electrospray ionization ion trap time-of-flight mass spectrometry technique for glutathione determination.

George A Zachariadis1, Erwin Rosenberg.   

Abstract

RATIONALE: The capabilities of modified non-spherical Doehlert-type experimental designs to optimize the performance of a hybrid mass spectrometer were investigated in this paper for the first time. The optimization process was completed in three successive steps with groups of variables avoiding any univariable approach. Glutathione (GSH, reduced) was selected as a very interesting analyte since it is considered to be one of the most abundant tripeptides in human organism and its action against xenobiotics and oxidative radicals is well known.
METHODS: In particular, a tandem technique based on sequential ion management by an ion trap followed by a time-of-flight mass analyzer (ITTOFMS) was introduced commercially in recent years and investigated for glutathione determination. Glutathione was injected in a stream of a typical mobile phase used in liquid chromatography (LC) and analyzed after electrospray ionization (ESI) in tandem MS.
RESULTS: The three main steps of the LC/MS system, namely the LC mobile phase, the ESI interface and the MS analyzer, were independently optimized in terms of maximum sensitivity. In this context quadratic models were found and their prediction power was evaluated. A calibration study was performed at default and optimum conditions in order to quantitatively estimate the sensitivity enhancement of the employed technique for this analyte. Satisfactory precision (RSD 5.7%) and detectability (LOD 0.07 µmol L(-1) ) were achieved.
CONCLUSIONS: The results highlighted the possibilities offered by the employment of multifactorial optimization towards the improvement of performance of tandem mass spectrometry techniques.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23280982     DOI: 10.1002/rcm.6475

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Definitive Screening Design Optimization of Mass Spectrometry Parameters for Sensitive Comparison of Filter and Solid Phase Extraction Purified, INLIGHT Plasma N-Glycans.

Authors:  Elizabeth S Hecht; James P McCord; David C Muddiman
Journal:  Anal Chem       Date:  2015-06-30       Impact factor: 6.986

Review 2.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

3.  Silver-Nanoparticle-Embedded Porous Silicon Disks Enabled SERS Signal Amplification for Selective Glutathione Detection.

Authors:  Yang Bu; Guixian Zhu; Shengliang Li; Ruogu Qi; Gauri Bhave; Dechen Zhang; Ruixuan Han; Dali Sun; Xiangfeng Liu; Zhongbo Hu; Xuewu Liu
Journal:  ACS Appl Nano Mater       Date:  2017-12-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.