Literature DB >> 23279576

Is preoperative ciliary body and iris anatomical configuration a predictor of malignant glaucoma development?

Tiago S Prata1, Syril Dorairaj, Carlos G V De Moraes, Siddhart Mehta, Zaher Sbeity, Celso Tello, Jeffrey Liebmann, Robert Ritch.   

Abstract

BACKGROUND: To investigate anatomical configuration of ciliary body and iris using ultrasound biomicroscopy as a predictor of malignant glaucoma development.
DESIGN: Retrospective study in a tertiary care hospital. PARTICIPANTS: Cohort of 31 consecutive patients diagnosed with post-surgical malignant glaucoma.
METHODS: Anterior chamber angle, iris and ciliary body configuration of involved eyes that had ultrasound biomicroscopy evaluation prior to the malignant glaucoma onset were evaluated. In cases with no presurgical ultrasound biomicroscopy exam of the involved eye, images from the fellow eye (imaged within 6 months) were analysed. MAIN OUTCOME MEASURES: Qualitative parameters.
RESULTS: Thirty-one eyes (31 patients) had confirmed malignant glaucoma between 1996 and 2008. Most patients were women (65%) and had an anatomical narrow angle or angle-closure glaucoma (77%). Mean intraocular pressure at diagnosis was 30.4 ± 13.5 mmHg. The most common operation was trabeculectomy with mitomycin C (55%, 17/31 eyes), combined (3/17) or not (14/17) with cataract extraction and intraocular lens implantation. Among these 31 cases, we were able to evaluate the ultrasound biomicroscopy images of 13 patients (13 eyes) including involved eyes imaged prior to the malignant glaucoma onset or eligible fellow eyes. A narrow angle with or without iridotrabecular contact was found in all eyes. A large and/or anteriorly positioned ciliary body associated with an iris root angulating forward and centrally, revealing a plateau iris configuration, was noticed in 85% (11/13) of these eyes.
CONCLUSION: Identification of plateau iris configuration by ultrasound biomicroscopy should be considered as a possible predictor of post-operative malignant glaucoma development.
© 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  malignant glaucoma; plateau iris configuration; ultrasound biomicroscopy

Mesh:

Year:  2013        PMID: 23279576     DOI: 10.1111/ceo.12057

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  12 in total

1.  Intraoperative malignant glaucoma during femtosecond laser-assisted cataract surgery: A case report.

Authors:  Rong Xu; Danmin Cao; Ya Jiao; Qingyan Zeng
Journal:  Medicine (Baltimore)       Date:  2022-06-24       Impact factor: 1.817

2.  Application of Nd:YAG laser to the anterior vitreous in malignant glaucoma - a systemic review and meta-analysis.

Authors:  Margarita Safir; Idan Hecht; Tal Sharon; Adi Einan-Lifshitz; Avner Belkin
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-03-29       Impact factor: 3.535

3.  Effectiveness of surgical management of malignant glaucoma in phakic eyes.

Authors:  Qi-Wei Wang; Cheng-Guo Zuo; Jing Li; Xiao-Shan Lin; Wan Chen; Qiao-Lin Zhu; Feng-Qi Zhou; Hao-Tian Lin; Wei-Rong Chen
Journal:  Int J Ophthalmol       Date:  2022-01-18       Impact factor: 1.779

4.  Repeatability and Reliability of Quantified Ultrasound Biomicroscopy Image Analysis of the Ciliary Body at the Pars Plicata.

Authors:  Joy Li; Jennifer Drechsler; Anna Lin; Matthew Widlus; Azam Qureshi; Gianna Stoleru; Osamah Saeedi; M Roni Levin; Mona Kaleem; Mohamad Jaafar; William P Madigan; Janet Leath Alexander
Journal:  Ultrasound Med Biol       Date:  2021-04-13       Impact factor: 3.694

5.  Anterior vitrectomy, phacoemulsification cataract extraction and irido-zonulo-hyaloid-vitrectomy in protracted acute angle closure crisis.

Authors:  Xiaowei Yu; Zhenni Zhao; Dandan Zhang; Xue Yang; Nannan Sun; Yixiu Lin; Jiamin Zhang; Zhigang Fan
Journal:  Int Ophthalmol       Date:  2021-04-27       Impact factor: 2.031

6.  Deep Learning for Anterior Segment Optical Coherence Tomography to Predict the Presence of Plateau Iris.

Authors:  Boonsong Wanichwecharungruang; Natsuda Kaothanthong; Warisara Pattanapongpaiboon; Pantid Chantangphol; Kasem Seresirikachorn; Chaniya Srisuwanporn; Nucharee Parivisutt; Andrzej Grzybowski; Thanaruk Theeramunkong; Paisan Ruamviboonsuk
Journal:  Transl Vis Sci Technol       Date:  2021-01-06       Impact factor: 3.283

7.  Anterior segment ultrasound biomicroscopy image analysis using ImageJ software: Intra-observer repeatability and inter-observer agreement.

Authors:  Azam Qureshi; Haoxing Chen; Osamah Saeedi; Mona A Kaleem; Gianna Stoleru; Jordan Margo; Sachin Kalarn; Janet L Alexander
Journal:  Int Ophthalmol       Date:  2018-03-07       Impact factor: 2.031

Review 8.  Acute and chronic fluid misdirection syndrome: pathophysiology and treatment.

Authors:  Andrzej Grzybowski; Piotr Kanclerz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-06       Impact factor: 3.535

9.  Phacoemulsification with Intraocular Implantation of Lens, Endocyclophotocoagulation, and Endoscopic-Goniosynechialysis (PIECES): A Combined Technique for the Management of Extensive Synechial Primary Angle Closure Glaucoma.

Authors:  Pouya Alaghband; Ian As Rodrigues; Saurabh Goyal
Journal:  J Curr Glaucoma Pract       Date:  2018-03-01

10.  Evaluation of Two Different Anterior Vitrectomies for Fluid Misdirection Syndrome Secondary to Cataract Surgery Combined with Goniosynechialysis.

Authors:  Zhenbin Qian; Yau Kei Chan; Liqing Wei; Bin Zheng; Li Nie; Weihua Pan
Journal:  J Ophthalmol       Date:  2020-03-23       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.