Literature DB >> 23279136

Ex vivo high-definition optical coherence tomography of basal cell carcinoma compared to frozen-section histology in micrographic surgery: a pilot study.

T Maier1, D Kulichová, T Ruzicka, C Kunte, C Berking.   

Abstract

BACKGROUND: Micrographic surgery is an established, but time-consuming operating procedure for facial basal cell carcinoma (BCC). A new high-definition (HD) optical coherence tomography (OCT) with high lateral and axial resolution in a horizontal (en-face) and vertical (slice) imaging mode allows a fast and non-invasive in vivo examination of BCC.
OBJECTIVES: To compare the diagnosis of BCC in excised tissue ex vivo by high-definition optical coherence tomography (HD-OCT) with the findings of frozen-section histology in micrographic surgery.
METHODS: Twenty freshly excised BCC were examined by HD-OCT in the en-face and slice imaging mode divided into four sections each in concordance with the four excision margins of histography, and subsequently processed for conventional micrographic evaluation.
RESULTS: A total of 80 HD-OCT images of 20 BCCs were evaluated and in 45% (9/20) HD-OCT correlated perfectly with the histography results. The sensitivity and specificity for the 80 evaluated HD-OCT images were 74% and 64% respectively.
CONCLUSIONS: High-definition optical coherence tomography allows the postoperative identification of BCC in excised tissue ex vivo, but has still limitations in the recognition of tumour margins in comparison with the micrographic evaluation of frozen sections.
© 2013 The Authors. Journal of the European Academy of Dermatology and Venereology © 2013 European Academy of Dermatology and Venereology.

Entities:  

Mesh:

Year:  2012        PMID: 23279136     DOI: 10.1111/jdv.12063

Source DB:  PubMed          Journal:  J Eur Acad Dermatol Venereol        ISSN: 0926-9959            Impact factor:   6.166


  5 in total

1.  Automated identification of basal cell carcinoma by polarization-sensitive optical coherence tomography.

Authors:  Lian Duan; Tahereh Marvdashti; Alex Lee; Jean Y Tang; Audrey K Ellerbee
Journal:  Biomed Opt Express       Date:  2014-09-22       Impact factor: 3.732

Review 2.  [Optical coherence tomography].

Authors:  T von Braunmühl
Journal:  Hautarzt       Date:  2015-07       Impact factor: 0.751

3.  Review of intraoperative optical coherence tomography: technology and applications [Invited].

Authors:  Oscar M Carrasco-Zevallos; Christian Viehland; Brenton Keller; Mark Draelos; Anthony N Kuo; Cynthia A Toth; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

4.  In vivo assessment of optical properties of basal cell carcinoma and differentiation of BCC subtypes by high-definition optical coherence tomography.

Authors:  Marc Boone; Mariano Suppa; Makiko Miyamoto; Alice Marneffe; Gregor Jemec; Veronique Del Marmol
Journal:  Biomed Opt Express       Date:  2016-05-19       Impact factor: 3.732

5.  The clinical usefulness of optical coherence tomography during cancer interventions.

Authors:  Labrinus van Manen; Jouke Dijkstra; Claude Boccara; Emilie Benoit; Alexander L Vahrmeijer; Michalina J Gora; J Sven D Mieog
Journal:  J Cancer Res Clin Oncol       Date:  2018-06-20       Impact factor: 4.553

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.