Comparison of two in vivo measurements for skin surface topography.

Jan Kottner1, Marianne Schario, Natalie Garcia Bartels, Ellina Pantchechnikova, Kathrin Hillmann, Ulrike Blume-Peytavi.   

Abstract

BACKGROUND/
PURPOSE: Non-contact methods for quantifying skin surface topography in vivo are common in skin research. The surface evaluation of living skin (SELS) and the phaseshift rapid in vivo measurement of skin (PRIMOS) are two approaches to measure skin surface roughness and wrinkling via optical methods. The aim of this study was to compare the reliability and interrelatedness of the parameters obtained by both technologies.
METHODS: Three repeated measurements were conducted on four skin areas (from distal to proximal) on the volar forearm skin in 12 healthy young subjects with two different instruments using the SELS and PRIMOS methods. Subjects mean age was 32.9 (SD 7.2) years. Skin phototypes were II (n = 7), III (n = 4), and IV (n = 1). The SELS parameters, smoothness (SEsm ), roughness (SEr ), scaliness (SEsc ), and wrinkles (SEw ), and a range of DIN/ISO surface roughness parameters were obtained. Intraclass correlation coefficients to estimate the reliabilities and correlation coefficients for estimating strengths and directions of relationships were applied.
RESULTS: Values of obtained parameters were very well comparable across the four skin areas. Reliability of the four SELS parameters was very high ranging between 0.95 and 1.00. Reliability coefficients for the roughness parameters varied between 0.35 and 1.00, whereas half of all PRIMOS estimates showed measurement errors less than 20%. SELS and the PRIMOS roughness parameters were largely unrelated.
CONCLUSION: Both measurement technologies provide reliable estimates indicating that skin surface measures of the volar forearm in young adults can differentiate between skin areas of different persons or different treatments in clinical studies. Skin surface topography of the volar forearm is comparable from distal to proximal assuring baseline comparability after randomization in clinical trials. SELS and PRIMOS roughness parameters of the volar forearm are not comparable and contain different types of information.
© 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 23279017     DOI: 10.1111/srt.12009

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  8 in total

1.  Image-based haptic roughness estimation and rendering for haptic palpation from in vivo skin image.

Authors:  Kwangtaek Kim
Journal:  Med Biol Eng Comput       Date:  2017-08-08       Impact factor: 2.602

2.  Release of sodium pyruvate from sacral prophylactic dressings: A computational model.

Authors:  Ayelet Levy; Jan Kottner; Amit Gefen
Journal:  Int Wound J       Date:  2019-05-07       Impact factor: 3.315

3.  Skin measurement devices to assess skin quality: A systematic review on reliability and validity.

Authors:  Mirte Langeveld; Lara S van de Lande; Eimear O' Sullivan; Berend van der Lei; Joris A van Dongen
Journal:  Skin Res Technol       Date:  2021-11-09       Impact factor: 2.240

Review 4.  Mesenchymal Stem Cells from Adipose Tissue in Clinical Applications for Dermatological Indications and Skin Aging.

Authors:  Meenakshi Gaur; Marek Dobke; Victoria V Lunyak
Journal:  Int J Mol Sci       Date:  2017-01-20       Impact factor: 5.923

Review 5.  Optical Technologies for the Improvement of Skin Cancer Diagnosis: A Review.

Authors:  Laura Rey-Barroso; Sara Peña-Gutiérrez; Carlos Yáñez; Francisco J Burgos-Fernández; Meritxell Vilaseca; Santiago Royo
Journal:  Sensors (Basel)       Date:  2021-01-02       Impact factor: 3.576

6.  The weather-beaten dorsal hand clinical rating, shadow casting optical profilometry, and skin capacitance mapping.

Authors:  Marie Delvenne; Claudine Piérard-Franchimont; Laurence Seidel; Adelin Albert; Gérald E Piérard
Journal:  Biomed Res Int       Date:  2013-10-03       Impact factor: 3.411

Review 7.  A systematic review of objective burn scar measurements.

Authors:  Kwang Chear Lee; Janine Dretzke; Liam Grover; Ann Logan; Naiem Moiemen
Journal:  Burns Trauma       Date:  2016-04-27

8.  Scientific validation of three-dimensional stereophotogrammetry compared to the IGAIS clinical scale for assessing wrinkles and scars after laser treatment.

Authors:  Barbara Helena Barcaro Machado; Ivy Dantas De Melo E Silva; Walter Marou Pautrat; James Frame; Mohammad Najlah
Journal:  Sci Rep       Date:  2021-06-11       Impact factor: 4.379