Literature DB >> 23276437

Relationship between oxygen saturation and umbilical cord pH immediately after birth.

Sinan Uslu1, Ali Bulbul, Emrah Can, Umut Zubarioglu, Ozgul Salihoglu, Asiye Nuhoglu.   

Abstract

BACKGROUND: The aim of this study is to determine the relationship between oxygen saturation (SpO(2)) by pulse oximetry levels and umbilical cord arterial pH values in healthy newborns during the first 15 minutes of life.
METHODS: The study was performed with healthy term, appropriate-for-gestational-age newborn infants. The infants were divided in two groups: umbilical cord arterial blood pH value ≤7.19 (group 1) and >7.19 (group 2); SpO(2) levels during the first 15 minutes of life were compared between groups.
RESULTS: The study was completed with 129 infants (33 in group 1 and 96 in group 2). A significant correlation was found between first-measured preductal and postductal SpO(2) levels by pulse oximetry and umbilical cord arterial pH values ([r²:0.72(0.62 -0.79); p < 0.001] and [r²:0.32(0.25 - 0.54); p < 0.001], respectively). In group 1, infants had lower SpO(2) levels at both preductal and postductal measurements during the first 11 minutes of life and time to reach ≥90% SpO(2) level was longer compared with infants in group 2.
CONCLUSION: Determination of umbilical arterial blood pH values, in addition to clinical findings and oxygen saturation measurements, might be helpful in deciding the concentration of oxygen and whether or not to continue oxygen supplementation in the delivery room.
Copyright © 2012. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23276437     DOI: 10.1016/j.pedneo.2012.08.005

Source DB:  PubMed          Journal:  Pediatr Neonatol        ISSN: 1875-9572            Impact factor:   2.083


  3 in total

1.  Sleep-related risk and worrying behaviours: a retrospective review of a tertiary centre's experience.

Authors:  Alessandro Vigo; Silvia Noce; Giulia Costagliola; Oliviero Bruni
Journal:  Eur J Pediatr       Date:  2019-09-04       Impact factor: 3.183

Review 2.  Fetal pulse oximetry for fetal assessment in labour.

Authors:  Christine E East; Lisa Begg; Paul B Colditz; Rosalind Lau
Journal:  Cochrane Database Syst Rev       Date:  2014-10-07

3.  Perinatal Arterial Ischemic Stroke Is Associated to Materno-Fetal Immune Activation and Intracranial Arteritis.

Authors:  Clémence Guiraut; Nicole Cauchon; Martin Lepage; Guillaume Sébire
Journal:  Int J Mol Sci       Date:  2016-11-25       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.