Literature DB >> 23274619

Comparison of plastic and metallic single-use and metallic reusable laryngoscope blades: a randomised controlled trial.

Clément Buléon1, Jean-Jacques Parienti, Anne Lesage, Wilfried Grandin, Emmanuel Pouliquen, Frédéric Flais, Thérèse Simonet, Jean-Louis Gérard, Jean-Luc Hanouz.   

Abstract

CONTEXT: Plastic single-use laryngoscope blades have been found to increase the difficulty of intubation. Metallic single-use blades may represent an alternative.
OBJECTIVE: To compare the rates of intubation failure at first laryngoscopy using metallic single-use, plastic single-use and metallic reusable laryngoscope blades.
DESIGN: Randomised, superiority, single-centre, controlled trial.
SETTING: Operating theatres at a University Hospital from January 2008 to August 2009. PATIENTS: A total of 1863 adults requiring general anaesthesia. INTERVENTION: Patients were randomised to one of three laryngoscope blades: metallic single-use, plastic single-use or metallic reusable. MAIN OUTCOME MEASURE: The primary end-point was the number of intubation failures at first laryngoscopy. Secondary end-points were glottic exposure and the Intubation Difficulty Scale.
RESULTS: The failure rate (absolute difference: 95% confidence interval) at the first attempt was greater for the plastic single-use blades (8.1%) than for the metallic reusable [3.2% (4.9%: 2.2 to 7.6%); P < 0.001] and metallic reusable blades [4.0% (4.0%: 1.2 to 6.9%); P < 0.006]. No difference was found between the metallic reusable and metallic single-use groups (0.9%: -1.3 to 3.1%). Scoring on the Intubation Difficulty Scale [median (interquartile range)] was higher in the plastic single-use group [1 (0 to 2)] than in the metallic groups [metallic reusable: 0 (0 to 1); P < 0.001 and metallic single-use: 0 (0 to 1); P < 0.007] groups. Glottic exposure was significantly better in the metallic reusable group (modified Cormack &amp; Lehane score III and IV: 3.7%) compared with the plastic single-use group (modified Cormack &amp; Lehane score III and IV: 9.4%; P < 0.03).
CONCLUSION: The rates of failed intubation at first laryngoscopy were similar in the metallic reusable and metallic reusable groups, but greater in the plastic single-use group.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23274619     DOI: 10.1097/EJA.0b013e32835c1cdb

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  1 in total

1.  Laryngoscope decontamination techniques: A survey.

Authors:  Rajiv Chawla; Akhilesh Gupta; Anshu Gupta; Mritunjay Kumar
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2016 Jan-Mar
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.