Literature DB >> 23274136

Construction and organization of a BSL-3 cryo-electron microscopy laboratory at UTMB.

Michael B Sherman1, Juan Trujillo, Ian Leahy, Dennis Razmus, Robert Dehate, Paul Lorcheim, Mark A Czarneski, Domenica Zimmerman, Je T'aime M Newton, Andrew D Haddow, Scott C Weaver.   

Abstract

A unique cryo-electron microscopy facility has been designed and constructed at the University of Texas Medical Branch (UTMB) to study the three-dimensional organization of viruses and bacteria classified as select agents at biological safety level (BSL)-3, and their interactions with host cells. A 200keV high-end cryo-electron microscope was installed inside a BSL-3 containment laboratory and standard operating procedures were developed and implemented to ensure its safe and efficient operation. We also developed a new microscope decontamination protocol based on chlorine dioxide gas with a continuous flow system, which allowed us to expand the facility capabilities to study bacterial agents including spore-forming species. The new unified protocol does not require agent-specific treatment in contrast to the previously used heat decontamination. To optimize the use of the cryo-electron microscope and to improve safety conditions, it can be remotely controlled from a room outside of containment, or through a computer network world-wide. Automated data collection is provided by using JADAS (single particle imaging) and SerialEM (tomography). The facility has successfully operated for more than a year without an incident and was certified as a select agent facility by the Centers for Disease Control.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23274136      PMCID: PMC3593667          DOI: 10.1016/j.jsb.2012.12.007

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  30 in total

1.  EMAN: semiautomated software for high-resolution single-particle reconstructions.

Authors:  S J Ludtke; P R Baldwin; W Chiu
Journal:  J Struct Biol       Date:  1999-12-01       Impact factor: 2.867

2.  Angular reconstitution: a posteriori assignment of projection directions for 3D reconstruction.

Authors:  M Van Heel
Journal:  Ultramicroscopy       Date:  1987       Impact factor: 2.689

3.  Optimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy.

Authors:  Peter B Rosenthal; Richard Henderson
Journal:  J Mol Biol       Date:  2003-10-31       Impact factor: 5.469

4.  UCSF Chimera--a visualization system for exploratory research and analysis.

Authors:  Eric F Pettersen; Thomas D Goddard; Conrad C Huang; Gregory S Couch; Daniel M Greenblatt; Elaine C Meng; Thomas E Ferrin
Journal:  J Comput Chem       Date:  2004-10       Impact factor: 3.376

5.  The SWISS-MODEL workspace: a web-based environment for protein structure homology modelling.

Authors:  Konstantin Arnold; Lorenza Bordoli; Jürgen Kopp; Torsten Schwede
Journal:  Bioinformatics       Date:  2005-11-13       Impact factor: 6.937

6.  Automated electron microscope tomography using robust prediction of specimen movements.

Authors:  David N Mastronarde
Journal:  J Struct Biol       Date:  2005-10       Impact factor: 2.867

7.  Mapping the structure and function of the E1 and E2 glycoproteins in alphaviruses.

Authors:  Suchetana Mukhopadhyay; Wei Zhang; Stefan Gabler; Paul R Chipman; Ellen G Strauss; James H Strauss; Timothy S Baker; Richard J Kuhn; Michael G Rossmann
Journal:  Structure       Date:  2006-01       Impact factor: 5.006

8.  The Fusion glycoprotein shell of Semliki Forest virus: an icosahedral assembly primed for fusogenic activation at endosomal pH.

Authors:  J Lescar; A Roussel; M W Wien; J Navaza; S D Fuller; G Wengler; G Wengler; F A Rey
Journal:  Cell       Date:  2001-04-06       Impact factor: 41.582

Review 9.  Transmission electron microscopy of frozen hydrated biological material.

Authors:  M Stewart
Journal:  Electron Microsc Rev       Date:  1989

10.  Structure of the recombinant alphavirus Western equine encephalitis virus revealed by cryoelectron microscopy.

Authors:  Michael B Sherman; Scott C Weaver
Journal:  J Virol       Date:  2010-07-14       Impact factor: 5.103

View more
  3 in total

Review 1.  Viral Infection at High Magnification: 3D Electron Microscopy Methods to Analyze the Architecture of Infected Cells.

Authors:  Inés Romero-Brey; Ralf Bartenschlager
Journal:  Viruses       Date:  2015-12-03       Impact factor: 5.048

2.  Structures of enveloped virions determined by cryogenic electron microscopy and tomography.

Authors:  Robert Stass; Weng M Ng; Young Chan Kim; Juha T Huiskonen
Journal:  Adv Virus Res       Date:  2019-08-20       Impact factor: 9.937

3.  Cryofixation of Inactivated Hantavirus-Infected Cells as a Method for Obtaining High-Quality Ultrastructural Preservation for Electron Microscopic Studies.

Authors:  Amar Parvate; Ranjan Sengupta; Evan P Williams; Yi Xue; Yong-Kyu Chu; Robert V Stahelin; Colleen B Jonsson
Journal:  Front Cell Infect Microbiol       Date:  2020-11-06       Impact factor: 5.293

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.