Literature DB >> 23273363

Quantification of external root resorption by low- vs high-resolution cone-beam computed tomography and periapical radiography: A volumetric and linear analysis.

Stacy N Ponder1, Erika Benavides, Sunil Kapila, Nan E Hatch.   

Abstract

INTRODUCTION: The goal of this study was to determine whether cone beam-computed tomography (CBCT) images with resolutions similar to those produced in orthodontic offices have sufficient resolution to accurately quantify root resorption defects.
METHODS: Teeth containing simulated root defects were scanned by microcomputed tomography (microCT) and CBCT at 0.2- and 0.4-mm resolutions and were radiographed by the periapical technique. Root length was measured with digital calipers. Comparisons were made to establish significance between imagining modalities and to compare defects of differing severity and position.
RESULTS: The mean absolute difference in volumetric measurements of lateral defects from 0.2-mm-resolution CBCT images compared with those from microCT images was significantly smaller than those from 0.4-mm-resolution CBCT images (0.20 ± 0.2 mm(3) vs 0.30 ± 0.3 mm(3); P = 0.002). A Bland-Altman analysis showed that the 95% limits of agreement range between low-resolution CBCT and microCT volumetric measurements was1.44-fold greater than that between high-resolution CBCT and microCT measurements (-0.87-0.68 vs -0.49-0.59 mm(3)). The accuracy of the volumetric measurements was also significantly influenced by defect size (P = 0.004 for high-resolution CBCT, P = 0.005 for low-resolution CBCT) and, on low-resolution scans, by the defect's vertical position (P = 0.012). Linear measurements of apical defects from both the 0.2- and 0.4-mm-resolution CBCT images were significantly more similar to the measurements made with digital calipers than the measurements from the periapical radiographs (P <0.0001 and P <0.0001, respectively).
CONCLUSIONS: Our results demonstrated that, compared with measurements from microCT images, high-resolution CBCT scans lead to more accurate volumetric quantifications of lateral resorption defects than do low-resolution scans. Both high- and low-resolution CBCT scans can also be used to more accurately measure external apical root resorption defects than periapical radiographs. Because these results are from CBCT scans of static images, measurements of root resorption defects from scans of patients will most likely be less accurate because of patient movement.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23273363     DOI: 10.1016/j.ajodo.2012.08.023

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  15 in total

Review 1.  CBCT in orthodontics: assessment of treatment outcomes and indications for its use.

Authors:  S D Kapila; J M Nervina
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

2.  Accuracy of linear and volumetric measurements of artificial ERR cavities by using CBCT images obtained at 4 different voxel sizes and measured by using 4 different software: an ex vivo research.

Authors:  Gül Sönmez; Cemre Koç; Kıvanç Kamburoğlu
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

3.  Letters From Our Readers.

Authors:  Marcio Rodrigues de Almeida
Journal:  Angle Orthod       Date:  2019-01       Impact factor: 2.079

4.  Cone beam CT evaluation of the presence of anatomic accessory canals in the jaws.

Authors:  M Eshak; S Brooks; N Abdel-Wahed; P C Edwards
Journal:  Dentomaxillofac Radiol       Date:  2014-02-26       Impact factor: 2.419

5.  The impact of rapid maxillary expansion on maxillary first molar root morphology of cleft subjects.

Authors:  Lucas Cardinal; Gabriela da Rosa Zimermann; Fausto Medeiros Mendes; Ildeu Andrade; Dauro Douglas Oliveira; Gladys Cristina Dominguez
Journal:  Clin Oral Investig       Date:  2017-05-09       Impact factor: 3.573

6.  Comparison of digital image displays performance in the detection of artificial internal root resorptions lesions.

Authors:  Matheus Nogueira da Hora; Lucas de Paula Lopes Rosado; Frederico Sampaio Neves; Ieda Crusoé-Rebello; Taruska Ventorini Vasconcelos
Journal:  Dentomaxillofac Radiol       Date:  2021-04-09       Impact factor: 3.525

7.  Crown and root lengths of incisors, canines, and premolars measured by cone-beam computed tomography in patients with malocclusions.

Authors:  Seon-Young Kim; Sung-Hoon Lim; Sung-Nam Gang; Hee-Jin Kim
Journal:  Korean J Orthod       Date:  2013-12-09       Impact factor: 1.372

Review 8.  Iatrogenic possibilities of orthodontic treatment and modalities of prevention.

Authors:  Nazeer Ahmed Meeran
Journal:  J Orthod Sci       Date:  2013-07

9.  Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols.

Authors:  Darren Forst; Simrit Nijjar; Carlos Flores-Mir; Jason Carey; Marc Secanell; Manuel Lagravere
Journal:  Prog Orthod       Date:  2014-12-23       Impact factor: 2.750

10.  Cone beam computed tomography study of apical root resorption induced by Herbst appliance.

Authors:  João Paulo Schwartz; Taísa Boamorte Raveli; Kélei Cristina de Mathias Almeida; Humberto Osvaldo Schwartz-Filho; Dirceu Barnabé Raveli
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.