Literature DB >> 2327332

The application of dustiness tests to the prediction of worker dust exposure.

W A Heitbrink1, W F Todd, T C Cooper, D M O'Brien.   

Abstract

Laboratory bench tests, known as dustiness tests, have been used to evaluate and compare the potential of various powders to cause occupational dust exposure. Dustiness tests are used to develop products with reduced dust emissions. The correlation between dustiness test results and dust exposures was evaluated at two bag dumping and bag filling operations. At one bag dumping and one bag filling operation, there was evidence of a relationship between dustiness test results and dust exposures. In one case, regression analysis showed that dust exposures could be predicted to within nearly one order of magnitude. The variability in this prediction was caused by the inherent variability in the occupational dust exposures. In the other case, there was evidence of a correlation after the data had been adjusted for the effect of varying drop height. At the remaining two operations, no correlation between dust exposures and dustiness test results were observed. These results indicate that the relevance of dustiness tests to occupational dust exposure needs to be evaluated at each site. Because a better option does not exist, manufacturers should continue to use empirical dustiness tests to develop better products in the laboratory. The conclusions reached in the laboratory need to be validated by dust exposure measurements in the field, however.

Mesh:

Substances:

Year:  1990        PMID: 2327332     DOI: 10.1080/15298669091369565

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  4 in total

1.  Computational Fluid Dynamics Analysis of the Venturi Dustiness Tester.

Authors:  Prahit Dubey; Urmila Ghia; Leonid A Turkevich
Journal:  Powder Technol       Date:  2017-05       Impact factor: 5.134

2.  A novel device for measuring respirable dustiness using low-mass powder samples.

Authors:  Patrick T O'Shaughnessy; Mitchell Kang; Daniel Ellickson
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

3.  Dustiness of fine and nanoscale powders.

Authors:  Douglas E Evans; Leonid A Turkevich; Cynthia T Roettgers; Gregory J Deye; Paul A Baron
Journal:  Ann Occup Hyg       Date:  2012-10-12

4.  Powder Intrinsic Properties as Dustiness Predictor for an Efficient Exposure Assessment?

Authors:  Neeraj Shandilya; Eelco Kuijpers; Ilse Tuinman; Wouter Fransman
Journal:  Ann Work Expo Health       Date:  2019-11-13       Impact factor: 2.179

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.