Literature DB >> 23271825

Automated closed loop control of inspired oxygen concentration.

Nelson Claure1, Eduardo Bancalari.   

Abstract

Oxygen therapy is extensively used in premature infants and adults with respiratory insufficiency. In the premature infant the goal during manual control of the F(IO(2)) is to maintain adequate oxygenation and to minimize the exposure to hypoxemia, hyperoxemia, and oxygen. However, this is frequently not achieved during routine care, which increases the risks of associated side effects affecting the eye, lungs, and central nervous system. In the adult the primary goal is to avoid hypoxemia, but conventional methods of oxygen supplementation may fall short during periods of increased demand. On the other hand, there are growing concerns related to unnecessarily high F(IO(2)) levels that increase the exposure to hyperoxemia and excessive oxygen use in settings where resources are limited. Systems for automated closed loop control of F(IO(2)) have been developed for use in neonates and adults. This paper will give an overview of the rationale for the development of these systems, present the evidence, and discuss important advantages and limitations.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23271825     DOI: 10.4187/respcare.01955

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  14 in total

1.  Fully automated predictive intelligent control of oxygenation (PRICO) in resuscitation and ventilation of preterm lambs.

Authors:  Matthias C Hütten; Tom G Goos; Daan Ophelders; Maria Nikiforou; Elke Kuypers; Monique Willems; Hendrik J Niemarkt; Jenny Dankelman; Peter Andriessen; Thilo Mohns; Irwin K M Reiss; Boris W Kramer
Journal:  Pediatr Res       Date:  2015-08-31       Impact factor: 3.756

Review 2.  Optimal oxygen titration in patients with chronic obstructive pulmonary disease: a role for automated oxygen delivery?

Authors:  François Lellouche; Jed Lipes; Erwan L'Her
Journal:  Can Respir J       Date:  2013 Jul-Aug       Impact factor: 2.409

Review 3.  Hemoglobin oxygen saturation targets in the neonatal intensive care unit: Is there a light at the end of the tunnel? 1.

Authors:  Payam Vali; Mark Underwood; Satyan Lakshminrusimha
Journal:  Can J Physiol Pharmacol       Date:  2018-10-26       Impact factor: 2.273

Review 4.  Oxygen targeting in preterm infants: a physiological interpretation.

Authors:  S Lakshminrusimha; V Manja; B Mathew; G K Suresh
Journal:  J Perinatol       Date:  2014-10-30       Impact factor: 2.521

5.  Automated oxygen titration and weaning with FreeO2 in patients with acute exacerbation of COPD: a pilot randomized trial.

Authors:  François Lellouche; Pierre-Alexandre Bouchard; Maude Roberge; Serge Simard; Erwan L'Her; François Maltais; Yves Lacasse
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2016-08-24

6.  Cost-effectiveness of FreeO2 in patients with chronic obstructive pulmonary disease hospitalised for acute exacerbations: analysis of a pilot study in Quebec.

Authors:  Thomas G Poder; Christian R C Kouakou; Pierre-Alexandre Bouchard; Véronique Tremblay; Sébastien Blais; François Maltais; François Lellouche
Journal:  BMJ Open       Date:  2018-01-23       Impact factor: 2.692

7.  A model for oxygen conservation associated with titration during pediatric oxygen therapy.

Authors:  Grace Wu; Alec Wollen; Stephen Himley; Glenn Austin; Jaclyn Delarosa; Rasa Izadnegahdar; Amy Sarah Ginsburg; Darin Zehrung
Journal:  PLoS One       Date:  2017-02-24       Impact factor: 3.240

8.  Feasibility and reliability of an automated controller of inspired oxygen concentration during mechanical ventilation.

Authors:  Kaouther Saihi; Jean-Christophe M Richard; Xavier Gonin; Thomas Krüger; Michel Dojat; Laurent Brochard
Journal:  Crit Care       Date:  2014-02-19       Impact factor: 9.097

9.  A randomised controlled trial of an automated oxygen delivery algorithm for preterm neonates receiving supplemental oxygen without mechanical ventilation.

Authors:  James Zapata; John Jairo Gómez; Robinson Araque Campo; Alejandro Matiz Rubio; Augusto Sola
Journal:  Acta Paediatr       Date:  2014-08-01       Impact factor: 2.299

10.  Automated versus manual oxygen titration in COPD exacerbation: machine or hands, this is the question.

Authors:  Gulsah Karaoren; Senay Goksu Tomruk; Antonio M Esquinas
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-04-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.