Abstract

The silicon photomultiplier (Si-PM) is a promising photodetector for PET. However, it remains unclear whether Si-PM can be used for a depth-of-interaction (DOI) detector based on the decay time differences of the scintillator where pulse shape analysis is used. For clarification, we tested the Hamamatsu 4 × 4 Si-PM array (S11065-025P) combined with scintillators that used different decay times to develop DOI block detectors using the pulse shape analysis. First, Ce-doped Gd(2)SiO(5) (GSO) scintillators of 0.5 mol% Ce were arranged in a 4 × 4 matrix and were optically coupled to the center of each pixel of the Si-PM array for measurement of the energy resolution as well as its gain variations according to the temperature. Then two types of Ce-doped Lu(1.9)Gd(0.1)Si0(5) (LGSO) scintillators, 0.025 mol% Ce (decay time: ~31 ns) and 0.75 mol% Ce (decay time: ~46 ns), were optically coupled in the DOI direction, arranged in a 11 × 7 matrix, and optically coupled to a Si-PM array for testing of the possibility of a high-resolution DOI detector. The energy resolution of the Si-PM array-based GSO block detector was 18 ± 4.4 % FWHM for a Cs-137 gamma source (662 keV). Less than 1 mm crystals were clearly resolved in the position map of the LGSO DOI block detector. The peak-to-valley ratio (P/V) derived from the pulse shape spectra of the LGSO DOI block detector was 2.2. These results confirmed that Si-PM array-based DOI block detectors are promising for high-resolution small animal PET systems.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23271446     DOI: 10.1007/s12194-012-0195-9

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  6 in total

1.  LaBr(3):Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time.

Authors:  Dennis R Schaart; Stefan Seifert; Ruud Vinke; Herman T van Dam; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2010-03-19       Impact factor: 3.609

2.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

3.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

4.  Simultaneous PET-MRI: a new approach for functional and morphological imaging.

Authors:  Martin S Judenhofer; Hans F Wehrl; Danny F Newport; Ciprian Catana; Stefan B Siegel; Markus Becker; Axel Thielscher; Manfred Kneilling; Matthias P Lichy; Martin Eichner; Karin Klingel; Gerald Reischl; Stefan Widmaier; Martin Röcken; Robert E Nutt; Hans-Jürgen Machulla; Kamil Uludag; Simon R Cherry; Claus D Claussen; Bernd J Pichler
Journal:  Nat Med       Date:  2008-03-23       Impact factor: 53.440

5.  Evaluation of Geiger-mode APDs for PET block detector designs.

Authors:  Armin Kolb; Eckart Lorenz; Martin S Judenhofer; Dieter Renker; Konrad Lankes; Bernd J Pichler
Journal:  Phys Med Biol       Date:  2010-03-05       Impact factor: 3.609

6.  Development of a Si-PM-based high-resolution PET system for small animals.

Authors:  Seiichi Yamamoto; Masao Imaizumi; Tadashi Watabe; Hiroshi Watabe; Yasukazu Kanai; Eku Shimosegawa; Jun Hatazawa
Journal:  Phys Med Biol       Date:  2010-09-16       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.