Extensor indicis proprius and extensor digitorum communis rupture after volar locked plating of the distal radius--a case report.

James P Ward1, L T Suezie Kim, Michael E Rettig.   

Abstract

Distal radius fractures are among the most commonly encountered fractures in the extremities. Volar plating of distal radius fracture has gained popularity in recent years with the introduction of the locked plating system. Complications of volar plating include extensor and flexor tendon rupture. Here we present a case report of an extensor indicis proprius and extensor digitorum communis to index finger tendon rupture after open reduction and internal fixation of distal radius fracture with locked plate.

Entities:  

Mesh:

Year:  2012        PMID: 23267455

Source DB:  PubMed          Journal:  Bull NYU Hosp Jt Dis        ISSN: 1936-9719