Ultrasmall superparamagnetic iron oxide: an intravenous contrast agent for assessing lymph nodes with MR imaging.

R Weissleder1, G Elizondo, J Wittenberg, A S Lee, L Josephson, T J Brady.   

Abstract

An ultrasmall superparamagnetic iron oxide (USPIO) preparation was evaluated as a potential intravenous contrast agent for lymph nodes. Relaxation time measurements and magnetic resonance (MR) imaging were performed in rats with normal lymph nodes and in rats with lymph node metastases. In normal animals, lymph node relaxation times decreased maximally within 24-48 hours after intravenous administration of USPIO. Twenty-four hours after administration, the T2 of normal lymph nodes had decreased from 74 msec +/- 2.2 to 30 msec +/- 0.7 (USPIO, 40 mumol of iron per kilogram) or 15 msec +/- 0.0 (200 mumol Fe/kg), whereas the T2 of metastatic nodes did not change. MR imaging of the animal model of nodal metastases confirmed the hypothesis that intravenously administered USPIO decreases signal intensity of normal but not metastatic nodes. A single intravenous administration of USPIO may allow detection of nodal metastases on the basis of signal intensity characteristics rather than the currently used, insensitive size characteristics.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2326475     DOI: 10.1148/radiology.175.2.2326475

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  87 in total

1.  Iron-oxide-enhanced MR lymphography: just a new toy or a breakthrough?

Authors:  B Hamm
Journal:  Eur Radiol       Date:  2002-03-22       Impact factor: 5.315

Review 2.  Computerised tomography in the staging of Hodgkin's disease and non-Hodgkin's lymphoma.

Authors:  Sarah J Vinnicombe; Rodney H Reznek
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-23       Impact factor: 9.236

Review 3.  Imaging the lymphatic system: possibilities and clinical applications.

Authors:  Olivier Clément; Alain Luciani
Journal:  Eur Radiol       Date:  2004-03-09       Impact factor: 5.315

Review 4.  Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

Authors:  Christine Rümenapp; Bernhard Gleich; Axel Haase
Journal:  Pharm Res       Date:  2012-03-06       Impact factor: 4.200

Review 5.  Preclinical lymphatic imaging.

Authors:  Fan Zhang; Gang Niu; Guangming Lu; Xiaoyuan Chen
Journal:  Mol Imaging Biol       Date:  2011-08       Impact factor: 3.488

6.  What is the pelvic lymph node normal size? Determination from normal MRI examinations.

Authors:  Marjorie Ramirez; Pierre Ingrand; Jean-Pierre Richer; Guillaume Herpe; Guillaume Vesselle; Samy Boucebci; Jean-Pierre Tasu
Journal:  Surg Radiol Anat       Date:  2015-10-29       Impact factor: 1.246

Review 7.  Recent Developments in Magnetic Diagnostic Systems.

Authors:  Hakho Lee; Tae-Hyun Shin; Jinwoo Cheon; Ralph Weissleder
Journal:  Chem Rev       Date:  2015-08-10       Impact factor: 60.622

Review 8.  Magnetic resonance molecular imaging with nanoparticles.

Authors:  Gregory M Lanza; Patrick M Winter; Shelton D Caruthers; Anne M Morawski; Anne H Schmieder; Katherine C Crowder; Samuel A Wickline
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

9.  pH-Sensitive MR Responses Induced by Dendron-Functionalized SPIONs.

Authors:  Indrajit Saha; Kathleen E Chaffee; Chuansong Duanmu; Brooke M Woods; Ashley M Stokes; Laura E Buck; Laura L Walkup; Narsimha Sattenapally; Jodi Huggenvik; Yong Gao; Boyd M Goodson
Journal:  J Phys Chem C Nanomater Interfaces       Date:  2012-12-21       Impact factor: 4.126

Review 10.  Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging.

Authors:  Omid Veiseh; Jonathan W Gunn; Miqin Zhang
Journal:  Adv Drug Deliv Rev       Date:  2009-11-10       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.