Thrombosis and cable damage in the HeartWare pump: clinical decisions and surgical technique.

Evgenij V Potapov1, Alexander Stepanenko, Friedrich Kaufmann, Ewald Henning, Juliana Vierecke, Elke Lehmkuhl, Roland Hetzer, Thomas Krabatsch.   

Abstract

Exchange of the HeartWare HVAD made necessary by thrombosis or cable damage is rare, but it is a complex procedure associated with morbidity. Less invasive exchange procedures may contribute to faster postoperative recovery and early mobilization. Between September 2009 and April 2012, 225 patients (median age 55.4 years, range 7-82 years, 40 of them women) were supported with the HeartWare HVAD at our institution. Cumulative follow-up in all 225 patients was 151.9 patient/years. In six patients, early pump thrombosis (<30 days) requiring pump exchange occurred after a median time of 7 (2-9) days. In six patients, late pump thrombosis requiring pump exchange occurred after a median of 380 (84-705) days. The overall incidence was 5.3% with 0.079 thromboses per year. In two instances of accidental cable damage as a result of massive external mechanical impact, pump exchange was necessary. We describe a safe and less invasive technique for the explantation and exchange of the HeartWare HVAD through a left thoracotomy. Pump thrombosis of the HeartWare HVAD is a very rare condition caused mostly by new onset of heparin-induced thrombocytopenia type II, mismanagement of anticoagulation, or hypercoagulability in the case of severe sepsis. Since the introduction of the sintered inflow cannula no early thrombosis has occurred. Pump exchange in the case of hemolysis should not be delayed. The cable of the HeartWare HVAD is very reliable and breaks only after excessive external impact. A minimally invasive approach for pump exchange on cardiopulmonary bypass for pump thrombosis and off-pump for cable damage or pump explantation is recommended.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23263342     DOI: 10.1097/MAT.0b013e31827c0d79

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

Review 1.  [Noncardiological surgical procedure for patients implanted with a ventricular assist device. Anesthesiological management concepts].

Authors:  F E Blum
Journal:  Med Klin Intensivmed Notfmed       Date:  2014-07-02       Impact factor: 0.840

Review 2.  [Ventricular long-term support with implantable continuous flow pumps: on the way to a gold standard in the therapy of terminal heart failure].

Authors:  T Krabatsch; E Potapov; S Soltani; M Dandel; V Falk; C Knosalla
Journal:  Herz       Date:  2015-04       Impact factor: 1.443

3.  Left ventricular assist devices exchange: why, when and how to do it-experience from experts.

Authors:  Bastian Schmack; Anton Sabashnikov; Alexander Weymann; Mohamed Zeriouh; Achim Koch; Arjang Ruhparwar; Andre Ruediger Simon; Aron Frederik Popov
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

Review 4.  Durability of continuous-flow left ventricular assist devices: a systematic review.

Authors:  Ashleigh Xie; Kevin Phan; Tristan D Yan
Journal:  Ann Cardiothorac Surg       Date:  2014-11

5.  Implantation of Short-Term and Long-Term Right Ventricular Assist Devices.

Authors:  Christiano Castello Branco Caldeira; Regimar Carla Machado; Debora Castello Branco Caldeira
Journal:  Braz J Cardiovasc Surg       Date:  2017 Sep-Oct
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.