Literature DB >> 23261952

Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI.

Andrada Ianuş1, Bernard Siow, Ivana Drobnjak, Hui Zhang, Daniel C Alexander.   

Abstract

Oscillating gradients provide an optimal probe of small pore sizes in diffusion MRI. While sinusoidal oscillations have been popular for some time, recent work suggests additional benefits of square or trapezoidal oscillating waveforms. This paper presents analytical expressions of the free and restricted diffusion signal for trapezoidal and square oscillating gradient spin echo (OGSE) sequences using the Gaussian phase distribution (GPD) approximation and generalises existing similar expressions for sinusoidal OGSE. Accurate analytical models are necessary for exploitation of these pulse sequences in imaging studies, as they allow model fitting and parameter estimation in reasonable computation times. We evaluate the accuracy of the approximation against synthesised data from the Monte Carlo (MC) diffusion simulator in Camino and Callaghan's matrix method and we show that the accuracy of the approximation is within a few percent of the signal, while providing several orders of magnitude faster computation. Moreover, since the expressions for trapezoidal wave are complex, we test sine and square wave approximations to the trapezoidal OGSE signal. The best approximations depend on the gradient amplitude and the oscillation frequency and are accurate to within a few percent. Finally, we explore broader applications of trapezoidal OGSE, in particular for non-model based applications, such as apparent diffusion coefficient estimation, where only sinusoidal waveforms have been considered previously. We show that with the right apodisation, trapezoidal waves also have benefits by virtue of the higher diffusion weighting they provide compared to sinusoidal gradients.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23261952     DOI: 10.1016/j.jmr.2012.11.021

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  20 in total

1.  Magnetic resonance imaging of mean cell size in human breast tumors.

Authors:  Junzhong Xu; Xiaoyu Jiang; Hua Li; Lori R Arlinghaus; Eliot T McKinley; Sean P Devan; Benjamin M Hardy; Jingping Xie; Hakmook Kang; A Bapsi Chakravarthy; John C Gore
Journal:  Magn Reson Med       Date:  2019-11-25       Impact factor: 4.668

2.  Diffusion-time dependence of diffusional kurtosis in the mouse brain.

Authors:  Manisha Aggarwal; Matthew D Smith; Peter A Calabresi
Journal:  Magn Reson Med       Date:  2020-02-05       Impact factor: 4.668

3.  Validation of surface-to-volume ratio measurements derived from oscillating gradient spin echo on a clinical scanner using anisotropic fiber phantoms.

Authors:  Gregory Lemberskiy; Steven H Baete; Martijn A Cloos; Dmitry S Novikov; Els Fieremans
Journal:  NMR Biomed       Date:  2017-03-22       Impact factor: 4.044

4.  Structural information revealed by the dispersion of ADC with frequency.

Authors:  Hua Li; Xiaoyu Jiang; Feng Wang; Junzhong Xu; John C Gore
Journal:  Magn Reson Imaging       Date:  2015-06-24       Impact factor: 2.546

Review 5.  Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome.

Authors:  Susie Y Huang; Thomas Witzel; Boris Keil; Alina Scholz; Mathias Davids; Peter Dietz; Elmar Rummert; Rebecca Ramb; John E Kirsch; Anastasia Yendiki; Qiuyun Fan; Qiyuan Tian; Gabriel Ramos-Llordén; Hong-Hsi Lee; Aapo Nummenmaa; Berkin Bilgic; Kawin Setsompop; Fuyixue Wang; Alexandru V Avram; Michal Komlosh; Dan Benjamini; Kulam Najmudeen Magdoom; Sudhir Pathak; Walter Schneider; Dmitry S Novikov; Els Fieremans; Slimane Tounekti; Choukri Mekkaoui; Jean Augustinack; Daniel Berger; Alexander Shapson-Coe; Jeff Lichtman; Peter J Basser; Lawrence L Wald; Bruce R Rosen
Journal:  Neuroimage       Date:  2021-08-28       Impact factor: 7.400

6.  Fast and robust measurement of microstructural dimensions using temporal diffusion spectroscopy.

Authors:  Hua Li; John C Gore; Junzhong Xu
Journal:  J Magn Reson       Date:  2014-02-19       Impact factor: 2.229

7.  In vivo imaging of cancer cell size and cellularity using temporal diffusion spectroscopy.

Authors:  Xiaoyu Jiang; Hua Li; Jingping Xie; Eliot T McKinley; Ping Zhao; John C Gore; Junzhong Xu
Journal:  Magn Reson Med       Date:  2016-08-06       Impact factor: 4.668

8.  Oscillating gradient diffusion MRI reveals unique microstructural information in normal and hypoxia-ischemia injured mouse brains.

Authors:  Dan Wu; Lee J Martin; Frances J Northington; Jiangyang Zhang
Journal:  Magn Reson Med       Date:  2014-08-28       Impact factor: 4.668

9.  Distinguishing neuronal from astrocytic subcellular microstructures using in vivo Double Diffusion Encoded 1H MRS at 21.1 T.

Authors:  Noam Shemesh; Jens T Rosenberg; Jean-Nicolas Dumez; Samuel C Grant; Lucio Frydman
Journal:  PLoS One       Date:  2017-10-02       Impact factor: 3.240

Review 10.  MR cell size imaging with temporal diffusion spectroscopy.

Authors:  Xiaoyu Jiang; Hua Li; Sean P Devan; John C Gore; Junzhong Xu
Journal:  Magn Reson Imaging       Date:  2020-12-16       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.