Literature DB >> 23261918

Comparison of single domain antibody immobilization strategies evaluated by surface plasmon resonance.

Scott A Walper1, P Audrey Brozozog Lee, Ellen R Goldman, George P Anderson.   

Abstract

The use of single domain antibodies (sdAbs) in place of conventional antibodies for both therapeutic and diagnostic applications continues to grow. SdAbs offer a number of advantages when compared to conventional antibodies such as their small size and low structural complexity which allows them to readily be produced as fusions in a variety formats. In this work we compared the utility of various C-terminal fusions and immobilization strategies for two sdAbs; one which recognizes ricin and the other EA1, an S-layer protein, of Bacillus anthracis. Comparisons were made between direct covalent attachment and affinity immobilization using a biotin-streptavidin interaction for the standard sdAb monomers, randomly and site-specifically biotinylated monomers, and fusion constructs of alkaline phosphatase dimers and streptavidin core tetramers. The sdAb binding and regeneration was evaluated by surface plasmon resonance in a multiplexed format. The construct that provided the highest density of active molecules by at least a factor of two was the sdAb-streptavidin core tetramer, followed by the sdAb-alkaline phosphatase and then the site-specifically biotinylated monomer. The poorest performing immobilization methods were the two most common, direct covalent attachment and the randomly biotinylated sdAb attached via NeutrAvidin. These improvements directly correlated to antigen capture in SPR assays. Similarly, the oriented immobilization method also translated to improvements in limit of detection assays using a bead-based system. The sdAb-streptavidin core provided more than a 100-fold improvement in the limit of detection of EA1, from ~200 ng/mL to to 1.6 ng/mL, while improvement for ricin detection was less but still a significant 5-fold decrease, going from 1.6 ng/mL down to 0.32 ng/mL. This demonstrated improvement in limits of detection is an advantage that should be transferable to most assay formats. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23261918     DOI: 10.1016/j.jim.2012.11.014

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  5 in total

1.  Conjugation of biotin-coated luminescent quantum dots with single domain antibody-rhizavidin fusions.

Authors:  Jinny L Liu; Scott A Walper; Kendrick B Turner; Audrey Brozozog Lee; Igor L Medintz; Kimihiro Susumu; Eunkeu Oh; Dan Zabetakis; Ellen R Goldman; George P Anderson
Journal:  Biotechnol Rep (Amst)       Date:  2016-03-03

Review 2.  Enhancing Stability of Camelid and Shark Single Domain Antibodies: An Overview.

Authors:  Ellen R Goldman; Jinny L Liu; Dan Zabetakis; George P Anderson
Journal:  Front Immunol       Date:  2017-07-25       Impact factor: 7.561

3.  Optimizing the Design of Diatom Biosilica-Targeted Fusion Proteins in Biosensor Construction for Bacillus anthracis Detection.

Authors:  Nicole R Ford; Yijia Xiong; Karen A Hecht; Thomas C Squier; Gregory L Rorrer; Guritno Roesijadi
Journal:  Biology (Basel)       Date:  2020-01-07

4.  Development and evaluation of single domain antibodies for vaccinia and the L1 antigen.

Authors:  Scott A Walper; Jinny L Liu; Daniel Zabetakis; George P Anderson; Ellen R Goldman
Journal:  PLoS One       Date:  2014-09-11       Impact factor: 3.240

5.  Optimizing Nanoplasmonic Biosensor Sensitivity with Orientated Single Domain Antibodies.

Authors:  Marc P Raphael; Joseph A Christodoulides; Jeff M Byers; George P Anderson; Jinny L Liu; Kendrick B Turner; Ellen R Goldman; James B Delehanty
Journal:  Plasmonics       Date:  2015-05-26       Impact factor: 2.404

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.