Literature DB >> 23259887

Minimally invasive vaginal hysterectomy using bipolar vessel sealing: preliminary experience with 500 cases.

G Ghirardini1, M Mohamed, A Bartolamasi, S Malmusi, E Dalla Vecchia, I Algeri, A Zanni, A Renzi, O Cavicchioni, A Braconi, F Pazzoni, C Alboni.   

Abstract

The objective of our study was to evaluate surgical outcome of minimally invasive vaginal hysterectomy (MIVH), using the bipolar vessel sealing system (BVSS; BiClamp®). The design was a retrospective analysis (Canadian Task-force Classification II-3). The setting was a secondary care hospital. Records of patients who underwent vaginal hysterectomy for benign indications in our centre between November 2005 and March 2011 were reviewed. The demographic patients' data, indications for surgery, patient history with regard to previous surgery, duration of surgery, blood loss (postoperative hemoglobin drop '∆Hb'), perioperative complications, and length of inpatient stay were collected from the medical records. The intervention was vaginal hysterectomy using BVSS (BiClamp®). Results showed that the mean duration of surgery was 48.9 ± 15.3 min (95% CI, 49.2-52.5). The mean duration of hospital stay was 3.2 ± 1.2 days (95% CI, 2.8-3.2). The mean ∆Hb was 1.4 ± 1.8 g/dl. Overall, conversion to laparotomy was required in three cases (0.6%). Only one haemoperitoneum occurred (0.2%) and this is the only case who required blood transfusion. The main indication for VH was uterine prolapse in 52.0% (n = 260) of cases; uterine fibroids in 37.4% (n = 187); adenomyosis uteri in 4.2% (n = 21); cervical dysplasia in 22 patients (4.4%) and in 2% (n = 10) of patients, endometrial hyperplasia and other pathologies were the indications for VH. It was concluded that electrosurgical bipolar vessel sealing by (BiClamp®) can provide a safe and feasible alternative to sutures in vaginal hysterectomy, resulting in reduced operative time and blood loss, with acceptable surgical outcomes.

Entities:  

Mesh:

Year:  2013        PMID: 23259887     DOI: 10.3109/01443615.2012.721027

Source DB:  PubMed          Journal:  J Obstet Gynaecol        ISSN: 0144-3615            Impact factor:   1.246


  2 in total

1.  The Decreasing Length of Hospital Stay following Vaginal Hysterectomy: 2011-2012 vs. 1996-1997 vs. 1995-1996.

Authors:  P Reif; T Drobnitsch; T Aigmüller; R Laky; D Ulrich; J Haas; A Bader; K Tamussino
Journal:  Geburtshilfe Frauenheilkd       Date:  2014-05       Impact factor: 2.915

2.  Vaginal Hysterectomy using the ERBE BiClamp® Bipolar Vessel Sealing System: A Case Series.

Authors:  Gillian V Blayney; James P Beirne; Lynsey Hinds; Declan Quinn; Gary J Dorman
Journal:  Ulster Med J       Date:  2017-09-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.