Literature DB >> 23258332

[Modified methylene blue method for measurement of hydrogen sulfide level in plasma].

Yang Zheng1, Feng Liao, Jun-Bao Du, Chao-Shu Tang, Guo-Heng Xu, Bin Geng.   

Abstract

In past decade, hydrogen sulfide (H₂S) as a novel gasotransmitter, covered many fields in biological and medical research. However, there is no effective, convenient and high-throughput method for determination of circulatory H₂S until now. Here, we aim to develop an easy method for measurement of circulatory H₂S by modified methylene blue method. In the present study, we added Zn²⁺ to plasma sample to deposit H₂S, HS⁻ and S²⁻, as well as plasma protein, then used NaOH to re-dissolve plasma protein. ZnS deposition was re-dissolved by the addition of N, N-dimethyl-p-phenylenediamine, and the remnant protein was deposited by trichloroacetic acid. After centrifugation, ferriammonium sulfate was added to the supernatant fluid to generate methylene blue, which was analyzed by spectrophotometer at 665 nm. Using the present method, we found that most ions including sulfate and thiosulfate did not affect detection of H₂S concentration, but albumin (physiological concentration) reduced the detection value, which suggested the binding of serum albumin and a certain amount of H₂S. The relative recovery ratio of present method is 81.9%, which implies that the method is relative accurate for the determination of H₂S concentration in plasma or serum. H₂S levels of frozen plasma samples from 65 healthy volunteers detected by the present method were (13.93 ± 4.98) µmol/L. There was no obvious difference between the detection values of fresh and frozen samples from the same SD rats. These results suggest the modified methylene blue assay is stable, sensitive, convenient and high-throughput. The method can be used to analyze the circulatory H₂S in clinical and basic research.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23258332

Source DB:  PubMed          Journal:  Sheng Li Xue Bao        ISSN: 0371-0874


  7 in total

1.  Measurement of H2S in vivo and in vitro by the monobromobimane method.

Authors:  Xinggui Shen; Gopi K Kolluru; Shuai Yuan; Christopher G Kevil
Journal:  Methods Enzymol       Date:  2015-01-10       Impact factor: 1.600

2.  Differential effects of subchronic acrylonitrile exposure on hydrogen sulfide levels in rat blood, brain, and liver.

Authors:  Bobo Yang; Changsheng Yin; Yu Zhang; Guangwei Xing; Suhua Wang; Fang Li; Michael Aschner; Rongzhu Lu
Journal:  Toxicol Res (Camb)       Date:  2022-04-05       Impact factor: 2.680

3.  Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry.

Authors:  Xinggui Shen; Sourav Chakraborty; Tammy R Dugas; Christopher G Kevil
Journal:  Nitric Oxide       Date:  2014-06-14       Impact factor: 4.427

4.  Interaction between hydrogen sulfide, nitric oxide, and carbon monoxide pathways in the bovine isolated retina.

Authors:  Madhura Kulkarni-Chitnis; Leah Mitchell-Bush; Remmington Belford; Jenaye Robinson; Catherine A Opere; Sunny E Ohia; Ya Fatou N Mbye
Journal:  AIMS Neurosci       Date:  2019-06-18

5.  Sensitivity and Selectivity Analysis of Fluorescent Probes for Hydrogen Sulfide Detection.

Authors:  Yingzhu Zhou; Federico Mazur; Kang Liang; Rona Chandrawati
Journal:  Chem Asian J       Date:  2022-01-27

6.  Hydrogen Sulfide Ameliorates Angiotensin II-Induced Atrial Fibrosis Progression to Atrial Fibrillation Through Inhibition of the Warburg Effect and Endoplasmic Reticulum Stress.

Authors:  Heng-Jing Hu; Xiu-Heng Wang; Yao Liu; Tian-Qing Zhang; Zheng-Rong Chen; Chi Zhang; Zhi-Han Tang; Shun-Lin Qu; Hui-Fang Tang; Zhi-Sheng Jiang
Journal:  Front Pharmacol       Date:  2021-12-07       Impact factor: 5.810

7.  Effect of changes in serum levels of endogenous hydrogen sulfide on fracture healing: Study protocol clinical trial (SPIRIT compliant).

Authors:  Feng Liao; Zongdong Zhu; Chengwei Xiao; Bo Tan; Xiaoming Tang; Dan Wei; Jiabin Yuan; Xuemei Xiang; Jiang Hu
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.