Literature DB >> 23258218

Commentary monitoring blood chemistry data in the Japanese national health and nutrition survey: a method and its significance.

Kazuhiko Kotani.   

Abstract

Entities:  

Mesh:

Year:  2012        PMID: 23258218      PMCID: PMC3700232          DOI: 10.2188/jea.je20120178

Source DB:  PubMed          Journal:  J Epidemiol        ISSN: 0917-5040            Impact factor:   3.211


× No keyword cloud information.
This issue of the Journal includes the report entitled Revised System to Evaluate Measurement of Blood Chemistry Data From the Japanese National Health and Nutrition Survey and Prefectural Health and Nutrition Surveys by Nakamura and colleagues.[1] Using quality control data recorded during 1999–2010, the authors calculated the total error (TE) for 14 blood chemistry items used in the Japanese National Health and Nutrition Survey (J-NHNS) and Prefectural Health and Nutrition Surveys.[1] TE levels were used to evaluate whether blood chemistry data in the 2011 surveys were acceptable, and the authors determined that the respective items were all within acceptable and/or borderline limits.[1] The authors propose that TE levels should be used to monitor blood chemistry data in the future.[1] Errors in blood biochemical measurements are unavoidable,[2] even though modern laboratories can considerably reduce such errors and clinical laboratory professionals carefully control data to minimize errors as part of their daily work. In addition, new analytical methods are continually being developed. In fact, the introduction of new analytical methods can affect the accuracy of blood chemistry items (eg, high-density lipoprotein cholesterol, creatinine).[1] However, healthcare providers are not always aware that some errors are unavoidable and that analytical methods are sometimes changed. The work of Nakamura et al[1] provides a rationale and method for comparing year-by-year blood chemistry data in the J-NHNS, a nationwide database of health-related information. If blood chemistry items show non-acceptable TE values in a certain year, researchers must take considerable care in sequentially comparing item data in that year with those in other years. TE has been used in the National Cholesterol Education Program in the United States.[3] It is calculated based on the accuracy and precision of blood chemistry items[1] and is considered a good approach for assessing the analytical performance of such items, since the accuracy (%bias) and precision (reproducibility) are simultaneously and comprehensively considered. The concept of TE can obviate the complex considerations required for separately specifying accuracy and precision in practical applications.[3] In addition, the tentative TE levels for the J-NHNS were previously reported by the first author of this report.[4] Compared with the previous report,[4] the current report[1] determines TE values for various blood chemistry items, with an increased number of blood chemistry items measured in the J-NHNS. Many of the present blood chemistry items have not been extensively studied, and therefore the system proposed in the current report may serve as a reference for other countries. Nationwide blood biochemistry data are a basic resource that can be used to describe national health status and, in turn, create new strategies for maintaining population health. For year-by-year observation of health status, various methodologies must be considered. The method proposed by Nakamura et al[1] will contribute to observation of long-term changes in blood chemistry data in national surveys. Subsequent monitoring of blood biochemistry data in the near future is now a realistic expectation.
  4 in total

1.  Establishment of long-term monitoring system for blood chemistry data by the national health and nutrition survey in Japan.

Authors:  Masakazu Nakamura; Shinichi Sato; Takashi Shimamoto; Masamitsu Konishi; Nobuo Yoshiike
Journal:  J Atheroscler Thromb       Date:  2008-10       Impact factor: 4.928

2.  Managing quality vs. measuring uncertainty in the medical laboratory.

Authors:  James O Westgard
Journal:  Clin Chem Lab Med       Date:  2010       Impact factor: 3.694

3.  National Cholesterol Education Program recommendations for measurement of low-density lipoprotein cholesterol: executive summary. The National Cholesterol Education Program Working Group on Lipoprotein Measurement.

Authors:  P S Bachorik; J W Ross
Journal:  Clin Chem       Date:  1995-10       Impact factor: 8.327

4.  Revised system to evaluate measurement of blood chemistry data from the Japanese National Health and Nutrition Survey and Prefectural Health and Nutrition Surveys.

Authors:  Masakazu Nakamura; Masahiko Kiyama; Akihiko Kitamura; Yoshinori Ishikawa; Shinichi Sato; Hiroyuki Noda; Nobuo Yoshiike
Journal:  J Epidemiol       Date:  2012-10-27       Impact factor: 3.211

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.