Literature DB >> 23253878

A biomechanical investigation of a knotless tension band in medial malleolar fracture models in composite Sawbones®.

John Clyde1, Victor Kosmopoulos, Brian Carpenter.   

Abstract

The present study introduces a knotless tension band construct and compares its biomechanical behavior with that of a traditional stainless steel tension band construct. Fourth-generation composite tibial Sawbones(®) were used in the present study. Fracture models were created to mimic Orthopaedic Trauma Association type 44-B2.2 ankle fractures. A total of 20 specimens were randomized evenly into a stainless steel tension band group (control group); or a knotless tension band group. The fixation constructs were mechanically tested, and the stiffness and failure strengths were calculated. Two failure strengths were determined: the engineering-based failure strength, defined as the greatest tensile load tolerated by the construct; and the clinical failure strength, defined as the force required to displace the fracture by 2 mm. We used 2-tailed independent samples t tests to compare and identify significant differences. The knotless tension band construct was 7.7% stronger and 33.2% stiffer and required a 36.7% greater force to displace the fracture by 2 mm. Independent sample t tests confirmed that differences in mean stiffness (p = .003) and clinical failure strength (p = .003) were statistically significant. Although the mean engineering strength for the knotless group was greater than that for the stainless steel group, this difference was not statistically significant (p = .170). This knotless tension band construct could potentially offer both clinical and biomechanical advantages compared with the current stainless steel standard.
Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23253878     DOI: 10.1053/j.jfas.2012.11.001

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  2 in total

1.  Medial malleolus: Operative Or Non-operative (MOON) trial protocol - a prospective randomised controlled trial of operative versus non-operative management of associated medial malleolus fractures in unstable fractures of the ankle.

Authors:  Thomas H Carter; William M Oliver; Catriona Graham; Andrew D Duckworth; Timothy O White
Journal:  Trials       Date:  2019-09-12       Impact factor: 2.279

2.  Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study.

Authors:  Michael W Downey; Kyle Duncan; Victor Kosmopoulos; Travis A Motley; Brian B Carpenter; Fadeke Ogunyankin; Alan Garrett
Journal:  Scientifica (Cairo)       Date:  2016-05-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.