Literature DB >> 23252706

Determinants of left ventricular vortex flow parameters assessed by contrast echocardiography in an in vivo animal model.

Dae-Hee Kim1, Jeong-Sook Seo, Yun-Sil Choi, Hye-Ran Kim, Youn-Ju Chung, Sung-Cheol Yun, Jong-Min Song, Duk-Hyun Kang, Jae-Kwan Song.   

Abstract

BACKGROUND: Various left ventricular (LV) vortex parameters obtained during contrast echocardiography (CE) have been recently described. The aim of this study was to investigate their determinants and associations with conventional hemodynamic variables.
METHODS: CE was performed and LV pressure was simultaneously measured during pharmacologic inotropic modulation in 8 mongrel dogs. Customized software was used to assess both vortex geometric parameters (vortex depth [VD], length [VL], width [VW], transverse position, and sphericity index [SI]) and pulsatility parameters (relative strength [RS], vortex relative strength [VRS], and vortex pulsation correlation [VPC]). The associations between each of these parameters and conventional indices representing LV systolic and diastolic function were analyzed.
RESULTS: VD and VW did not change significantly during pharmacologic modulation, whereas VL (P = 0.0034) and SI (P = 0.001) showed significant and progressive linear decreases from baseline during dobutamine infusion. Significant linear changes during positive and negative inotropic modulation were observed in all pulsatiliy parameters (P < 0.01 each). Geometric parameters were critically dependent on LV volume, with pulsatility parameters showing significant positive correlations with heart rate, systolic and diastolic blood pressure (DBP), dp/dtmax , early and late mitral inflow velocities, and peak systolic and diastolic annular velocities. In multivariate analysis, LV end-diastolic volume was a main determinant for VL (r = 0.29, P < 0.001) and VW (r = 0.65, P < 0.001), whereas dp/dtmax for pulsatility parameters (RS [r = 0.61, P < 0.001], VRS [r = 0.46, P < 0.001] and VPC [r = 0.62, P < 0.001]).
CONCLUSION: Geometric and pulsatility parameters differed in their association with LV geometry and conventional physiologic indices representing LV function. These differences should be considered in interpreting these variables.
© 2012, Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23252706     DOI: 10.1111/echo.12075

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

Review 1.  Fluid dynamics of ventricular filling in heart failure: overlooked problems of RV/LV chamber dilatation.

Authors:  Ares Pasipoularides
Journal:  Hellenic J Cardiol       Date:  2015 Jan-Feb

2.  Moving domain computational fluid dynamics to interface with an embryonic model of cardiac morphogenesis.

Authors:  Juhyun Lee; Mahdi Esmaily Moghadam; Ethan Kung; Hung Cao; Tyler Beebe; Yury Miller; Beth L Roman; Ching-Ling Lien; Neil C Chi; Alison L Marsden; Tzung K Hsiai
Journal:  PLoS One       Date:  2013-08-23       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.