| Literature DB >> 23250277 |
Román Bataller1, Inmaculada Campos, Nicolas Laguarda-Miro, Miguel Alcañiz, Juan Soto, Ramón Martínez-Máñez, Luís Gil, Eduardo García-Breijo, Javier Ibáñez-Civera.
Abstract
A new electronic tongue to monitor the presence of glyphosate (a non-selective systemic herbicide) has been developed. It is based on pulse voltammetry and consists in an array of three working electrodes (Pt, Co and Cu) encapsulated on a methacrylate cylinder. The electrochemical response of the sensing array was characteristic of the presence of glyphosate in buffered water (phosphate buffer 0.1 mol · dm-3, pH 6.7). Rotating disc electrode (RDE) studies were carried out with Pt, Co and Cu electrodes in water at room temperature and at pH 6.7 using 0.1 mol · dm-3 of phosphate as a buffer. In the presence of glyphosate, the corrosion current of the Cu and Co electrodes increased significantly, probably due to the formation of Cu2+ or Co2+ complexes. The pulse array waveform for the voltammetric tongue was designed by taking into account some of the redox processes observed in the electrochemical studies. The PCA statistical analysis required four dimensions to explain 95% of variance. Moreover, a two-dimensional representation of the two principal components differentiated the water mixtures containing glyphosate. Furthermore, the PLS statistical analyses allowed the creation of a model to correlate the electrochemical response of the electrodes with glyphosate concentrations, even in the presence of potential interferents such as humic acids and Ca2+. The system offers a PLS prediction model for glyphosate detection with values of 098, -2.3 × 10-5 and 0.94 for the slope, the intercept and the regression coefficient, respectively, which is in agreement with the good fit between the predicted and measured concentrations. The results suggest the feasibility of this system to help develop electronic tongues for glyphosate detection.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23250277 PMCID: PMC3571853 DOI: 10.3390/s121217553
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1.Chemical structure of glyphosate.
Concentration of samples prepared by addition of three selected compounds.
| 1 | 10 | 10 | 1 |
| 2 | 1 | 10 | 10 |
| 3 | 5 | 5 | 5 |
| 4 | 10 | 1 | 5 |
| 5 | 1 | 10 | 1 |
| 6 | 10 | 5 | 10 |
| 7 | 10 | 10 | 10 |
| 8 | 10 | 10 | 10 |
| 9 | 10 | 10 | 10 |
| 10 | 1 | 1 | 1 |
| 11 | 1 | 1 | 10 |
| 12 | 10 | 1 | 10 |
| 13 | 10 | 10 | 10 |
| 14 | 1 | 1 | 5 |
| 15 | 5 | 1 | 10 |
| 16 | 5 | 1 | 1 |
| 17 | 10 | 1 | 1 |
| 18 | 10 | 1 | 10 |
| 19 | 0 | 0 | 0 |
Figure 2.Copper and cobalt rotating disk electrode voltammograms of the solvent at pH 6.7, buffered with 0.1 M Na2PO4 (solid line) and 2.5 mM of glyphosate (discontinuous line) measured at 10 mV·s−1 and 1,500 rpm.
Figure 3.(a) Applied pulse sequence and (b) obtained response from glyphosate aqueous solutions (C = 5 × 10−3 mol·dm−3) using the Co and Cu electrodes (dashed line) and when the electrodes were rotating (continuous line) after subtracting the solvent signal.
Figure 4.Principal component analysis score plot for the rotating electrodes on different aqueous samples.
The adjusting parameters (r2, p1, p2 and RMSEP) from the PLS prediction models for the data from the validation set.
| Rotating electrodes | 0.876 | 1.01 | 9.1 × 10−5 | 3.6 × 10−4 |
| Static electrodes | 0.809 | 0.805 | 4.5 × 10−4 | 4.7 × 10−4 |
Figure 5.The results of the PLS prediction of glyphosate in phosphate buffer using (a) rotating electrodes, (a1) an extension of graph (a) and (b) PLS prediction of glyphosate using static electrodes.
The adjusting parameters (r2, p1, p2 and RMSEP) from the PLS prediction models for the data from the validation set.
| Glyphosate | 0.94 | 0.98 | −2.3 × 10−5 | 9.5 × 10−5 |
| Humic acids | 0.11 | 0.16 | 6.9 | 9.10 |
| Ca+2 | 0.13 | 0.47 | −0.93 | 22.18 |
Figure 6.The results of the PLS prediction of glyphosate in phosphate buffer using the electronic tongue and rotating disk electrodes.