A new "transducer-tipped" fiber optic catheter for measuring intramuscular pressures.

A G Crenshaw1, J R Styf, S J Mubarak, A R Hargens.   

Abstract

Laboratory and clinical tests were used to determine the efficacy of a new fiber optic "transducer-tipped" catheter for measuring intramuscular pressures. When pressures ranging from 0 to 250 mm Hg were applied by a mercury manometer, the fiber optic system accurately recorded the pressures. In addition, the fiber optic system showed long-term stability by accurately recording the manometer pressure over a 3 day period. The Slit system showed a higher magnitude of hydrostatic pressure artifacts with catheter tip movement as compared to the fiber optic system. The two catheters showed no difference when measuring pressures in pig muscle at rest or when being compressed throughout a range of 0 to 250 mm Hg. In human volunteers, both catheters measured essentially equal pressures at rest, during venous stasis, and during a combination of venous stasis and compression. For long-term assessment, the Slit system required as many as three saline flushes, whereas the fiber optic system measured pressures continuously without manipulation. We conclude that the fiber optic system is as accurate as the Slit catheter for measuring tissue fluid pressures at rest. In addition, the fiber optic system offers distinct advantages over conventional fluid-filled systems for measuring intramuscular pressures due to a lack of hydrostatic pressure artifacts caused by limb position and to the lack of flushing for long-term measurements.

Entities:  

Mesh:

Year:  1990        PMID: 2324863     DOI: 10.1002/jor.1100080318

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  6 in total

1.  Intramuscular pressures during exercise: an evaluation of a fiber optic transducer-tipped catheter system.

Authors:  A G Crenshaw; J R Styf; A R Hargens
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

2.  Evaluation of a fiber-optic technique for recording intramuscular pressure in the human leg.

Authors:  Andreas Nilsson; Qiuxia Zhang; Jorma Styf
Journal:  J Clin Monit Comput       Date:  2015-08-14       Impact factor: 2.502

Review 3.  Lumbar paraspinal compartment syndrome.

Authors:  Senthil T Nathan; Craig S Roberts; David Deliberato
Journal:  Int Orthop       Date:  2011-10-26       Impact factor: 3.075

4.  Performance characteristics of a new generation pressure microsensor for physiologic applications.

Authors:  Patrick S Cottler; Whitney R Karpen; Duane A Morrow; Kenton R Kaufman
Journal:  Ann Biomed Eng       Date:  2009-06-03       Impact factor: 3.934

5.  Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

Authors:  Shawn M O'Connor; Kenton R Kaufman; Samuel R Ward; Richard L Lieber
Journal:  Ann Biomed Eng       Date:  2020-10-01       Impact factor: 3.934

Review 6.  Optical Fibre Pressure Sensors in Medical Applications.

Authors:  Sven Poeggel; Daniele Tosi; DineshBabu Duraibabu; Gabriel Leen; Deirdre McGrath; Elfed Lewis
Journal:  Sensors (Basel)       Date:  2015-07-15       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.