Literature DB >> 23248176

The feasibility of home monitoring of impedance with the forced oscillation technique in chronic obstructive pulmonary disease subjects.

Sophie C Timmins1, Chantale Diba, Cindy Thamrin, Norbert Berend, Cheryl M Salome, Gregory G King.   

Abstract

Respiratory system resistance (Rrs) and reactance (Xrs) measured by forced oscillation technique (FOT) can be potentially used for home monitoring in COPD. Our aims were to determine the technical acceptability, adherence and variability of unsupervised, home FOT measurements over ten consecutive days. Supervised spirometry and FOT measurements were made on ten clinically stable COPD subjects at their homes at the study initiation. Subjects then self-recorded FOT twice daily for ten consecutive days with data transmitted to the laboratory server via a 3G mobile network. Subjects had a mean (SD) age of 68(8) years, smoking history 38.4(8.7) pack/years, post-bronchodilator FEV1 42.4(12.0)% predicted, FEV1/FVC ratio 0.45(0.10), mean Rrs 121.7(26.1)% predicted and mean Xrs 746.8(330.3)% predicted. The supervised measurements of mean Rrs and mean Xrs were similar to the unsupervised measurements (p = 0.34 and p = 0.92, respectively). 197 of 200 possible measurements were transmitted, all of which were deemed to be technically acceptable. The within-subject standard deviation, Sw, of Rrs-total and Xrs-total were 0.47 and 1.0 cmH(2)O L s(-1), respectively. Subjects who have COPD make reliable, unsupervised FOT measurements at home with a high degree of adherence. The day-to-day variability of FOT measurements was similar to that of supervised laboratory recordings. These results support the conduct of larger, longer-term studies of FOT monitoring in COPD.

Entities:  

Mesh:

Year:  2012        PMID: 23248176     DOI: 10.1088/0967-3334/34/1/67

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Discrepancy between in vivo and in vitro comparisons of forced oscillation devices.

Authors:  Sabine C Zimmermann; Joanna C Watts; Amy Bertolin; Kanika Jetmalani; Gregory G King; Cindy Thamrin
Journal:  J Clin Monit Comput       Date:  2017-07-31       Impact factor: 2.502

2.  Systems Biology and Clinical Practice in Respiratory Medicine. The Twain Shall Meet.

Authors:  Cindy Thamrin; Urs Frey; David A Kaminsky; Helen K Reddel; Andrew J E Seely; Béla Suki; Peter J Sterk
Journal:  Am J Respir Crit Care Med       Date:  2016-11-01       Impact factor: 21.405

3.  Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects.

Authors:  Joanna C Watts; Claude S Farah; Leigh M Seccombe; Blake M Handley; Robin E Schoeffel; Amy Bertolin; Jessica Dame Carroll; Gregory G King; Cindy Thamrin
Journal:  ERJ Open Res       Date:  2016-04-13

Review 4.  Pseudorandom Noise Forced Oscillation Technique to Assess Lung Function in Prematurely Born Children.

Authors:  Shannon Gunawardana; Christopher Harris; Anne Greenough
Journal:  Children (Basel)       Date:  2022-08-22

5.  On the respiratory mechanics measured by forced oscillation technique in patients with systemic sclerosis.

Authors:  Ingrid Almeida Miranda; Alvaro Camilo Dias Faria; Agnaldo José Lopes; José Manoel Jansen; Pedro Lopes de Melo
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.